Literature DB >> 20472844

Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.

Aileen P Morrison1, Milenko J Tanasijevic, Ellen M Goonan, Margaret M Lobo, Michael M Bates, Stuart R Lipsitz, David W Bates, Stacy E F Melanson.   

Abstract

Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.

Entities:  

Mesh:

Year:  2010        PMID: 20472844     DOI: 10.1309/AJCPC95YYMSLLRCX

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  11 in total

Review 1.  Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: a Laboratory Medicine Best Practices systematic review and meta-analysis.

Authors:  Susan R Snyder; Alessandra M Favoretto; James H Derzon; Robert H Christenson; Stephen E Kahn; Colleen S Shaw; Rich Ann Baetz; Diana Mass; Corinne R Fantz; Stephen S Raab; Milenko J Tanasijevic; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-06-28       Impact factor: 3.281

2.  Targeting Rejection: Analysis of Specimen Acceptability and Rejection, and Framework for Identifying Interventions in a Single Tertiary Healthcare Facility.

Authors:  Lisa Rooper; Jamal Carter; John Hargrove; Sheri Hoffmann; Stefan Riedel
Journal:  J Clin Lab Anal       Date:  2016-09-15       Impact factor: 2.352

3.  Establishing and evaluating bar-code technology in blood sampling system: a model based on human centered human-centered design method.

Authors:  Shin-Shang Chou; Hsiu-Fang Yan; Hsiu-Ya Huang; Kuan-Jui Tseng; Shu-Chen Kuo
Journal:  NI 2012 (2012)       Date:  2012-06-23

4.  The Efficacy of Patients' Wristband Bar-code on Prevention of Medical Errors: A Meta-analysis Study.

Authors:  M Khammarnia; A Kassani; M Eslahi
Journal:  Appl Clin Inform       Date:  2015-12-09       Impact factor: 2.342

5.  Pre-analytical Errors at the Chemical Pathology Laboratory of a Teaching Hospital.

Authors:  Marlene A Tapper; James C Pethick; Lowell L Dilworth; Donovan A McGrowder
Journal:  J Clin Diagn Res       Date:  2017-08-01

6.  Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.

Authors:  Aysenur Atay; Leyla Demir; Serap Cuhadar; Gulcan Saglam; Hulya Unal; Saliha Aksun; Banu Arslan; Asuman Ozkan; Recep Sutcu
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

7.  Improving diagnostic specimen management systems in an oral medicine department.

Authors:  Olivia Barratt; Melanie Simms; Miriam John; Michael Lewis; Phil Atkin
Journal:  BMJ Open Qual       Date:  2020-07

8.  Evaluation and implementation of QR Code Identity Tag system for Healthcare in Turkey.

Authors:  Vassilya Uzun; Sami Bilgin
Journal:  Springerplus       Date:  2016-08-30

9.  Reduction in Hospital-Wide Clinical Laboratory Specimen Identification Errors following Process Interventions: A 10-Year Retrospective Observational Study.

Authors:  Hsiao-Chen Ning; Chia-Ni Lin; Daniel Tsun-Yee Chiu; Yung-Ta Chang; Chiao-Ni Wen; Shu-Yu Peng; Tsung-Lan Chu; Hsin-Ming Yu; Tsu-Lan Wu
Journal:  PLoS One       Date:  2016-08-05       Impact factor: 3.240

10.  Changes in error rates in the Australian key incident monitoring and management system program.

Authors:  Stephanie Gay; Tony Badrick
Journal:  Biochem Med (Zagreb)       Date:  2020-04-15       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.