Literature DB >> 20471292

Comparison of neonatal MRI examinations with and without an MR-compatible incubator: advantages in examination feasibility and clinical decision-making.

Z Rona1, K Klebermass, F Cardona, C D Czaba, P C Brugger, M Weninger, A Pollak, D Prayer.   

Abstract

PURPOSE: To assess the utility of an MRI-compatible incubator (INC) by comparing.
METHODS: In a retrospective study, the clinical and radiological aspects of 129 neonatal MRI examinations during a 3 year period were analyzed. Routine protocols including fast spin-echo T2-weighted (w) sequences, axial T1w, Gradient-echo, diffusion sequences, and 3D T1 gradient-echo sequences were performed routinely, angiography and spectroscopy were added in some cases. Diffusion-tensor imaging was done in 50% of the babies examined in the INC and 26% without INC. Sequences, adapted from fetal MR-protocols were done in infants younger than 32 gestational weeks. Benefit from MR-information with respect to further management was evaluated.
RESULTS: The number of the examinations increased (30-99), while the mean age (43-38, 8 weeks of gestational age) and weight (3308-2766 g) decreased significantly with the use of the MR-compatible incubator. The mean imaging time (34, 43-30, 29 min) decreased, with a mean of one additionally performed sequence in the INC group. All infants received sedatives according to our anaesthetic protocol preceding imaging, but a repeated dose was never necessary (10% without INC) using the INC. Regarding all cases, MR-based changes in clinical management were initiated in 58%, while in 57% of cases the initial ultrasound diagnosis was changed or further specified.
CONCLUSIONS: The use of the INC enables the MR access of unstable infants with suspect CNS problems to the management, of whom is improved by MR information to significantly higher percentage, than without INC. Copyright (c) 2010 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20471292     DOI: 10.1016/j.ejpn.2010.03.005

Source DB:  PubMed          Journal:  Eur J Paediatr Neurol        ISSN: 1090-3798            Impact factor:   3.140


  9 in total

Review 1.  MRI evaluation and safety in the developing brain.

Authors:  Shannon Tocchio; Beth Kline-Fath; Emanuel Kanal; Vincent J Schmithorst; Ashok Panigrahy
Journal:  Semin Perinatol       Date:  2015-03-03       Impact factor: 3.300

2.  [Application of magnetic resonance imaging-compatible incubator in cranial magnetic resonance imaging for neonates: a multicenter prospective randomized clinical trial].

Authors:  Lian Liu; Peng Zhang; Hong-Ping Xia; Bin Wang; Xue-Ling Ma; Guo-Qiang Cheng; Yuan Shi
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2020-12

Review 3.  Diffusion MRI of the neonate brain: acquisition, processing and analysis techniques.

Authors:  Kerstin Pannek; Andrea Guzzetta; Paul B Colditz; Stephen E Rose
Journal:  Pediatr Radiol       Date:  2012-08-18

4.  An MRI system for imaging neonates in the NICU: initial feasibility study.

Authors:  Jean A Tkach; Noah H Hillman; Alan H Jobe; Wolfgang Loew; Ron G Pratt; Barret R Daniels; Suhas G Kallapur; Beth M Kline-Fath; Stephanie L Merhar; Randy O Giaquinto; Patrick M Winter; Yu Li; Machiko Ikegami; Jeffrey A Whitsett; Charles L Dumoulin
Journal:  Pediatr Radiol       Date:  2012-06-27

5.  Expert consensus on the clinical practice of neonatal brain magnetic resonance imaging.

Authors: 
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2022-01-15

6.  Clinical experience with an in-NICU magnetic resonance imaging system.

Authors:  Kirsten R Thiim; Elizabeth Singh; Srinivasan Mukundan; P Ellen Grant; Edward Yang; Mohamed El-Dib; Terrie E Inder
Journal:  J Perinatol       Date:  2022-04-22       Impact factor: 3.225

7.  Evaluation of 100 brain examinations using a 3 Tesla MR-compatible incubator-safety, handling, and image quality.

Authors:  Selma Sirin; Sophia L Goericke; Britta M Huening; Anja Stein; Sonja Kinner; Ursula Felderhoff-Mueser; Bernd Schweiger
Journal:  Neuroradiology       Date:  2013-08-07       Impact factor: 2.804

8.  Magnetic resonance imaging of neonates in the magnetic resonance compatible incubator.

Authors:  Monika Bekiesińska-Figatowska; Ewa Helwich; Magdalena Rutkowska; Joanna Stankiewicz; Iwona Terczyńska
Journal:  Arch Med Sci       Date:  2016-08-24       Impact factor: 3.318

9.  Fetal MRI versus postnatal imaging in the MR-compatible incubator.

Authors:  Monika Bekiesinska-Figatowska; Anna Romaniuk-Doroszewska; Agnieszka Duczkowska; Marek Duczkowski; Beata Iwanowska; Sylwia Szkudlińska-Pawlak
Journal:  Radiol Med       Date:  2016-06-02       Impact factor: 3.469

  9 in total