AIM: There are no published studies regarding sinus reactions to immediately loaded zygomatic implants. The aim of this study was to evaluate the maxillary sinus in a cohort of patients by means of clinical criteria and computerised tomography performed before surgery and after zygomatic implant placement (immediate function protocol).
MATERIALS AND METHODS: A total of 36 patients with 71 immediately loaded zygomatic implants were evaluated to find clinical criteria of maxillary sinus disturbance 13 to 42 months (average 21.9 months) after zygoma implant placement. A total of 44 implants had a machined surface and 27 had a porous titanium oxide surface. Twenty-six patients with 52 immediately loaded zygomatic implants were evaluated by means of a CT scan of the paranasal sinuses, 3 to 20 months (average 10.5 months) after zygomatic implant placement. All patients had no sinus symptoms before surgery and had a preoperative CT scan.
RESULTS: No clinical signs or symptoms of sinusitis were found. Radiological opacity of the antrum was found in two sinuses (out of 52), and minimal thickening of the Schneiderian membrane was found in 12 patients (out of 26). In eight of them, this was present in the preoperative CT scan.
CONCLUSIONS: Sinuses penetrated by zygomatic implants seem to maintain a normal physiology. However, in approximately 15 to 20% of patients, early radiological findings without clinical symptoms were observed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 20467644

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  4 in total

Review 1.  Survival and complications of zygomatic implants: a systematic review.

Authors:  Bruno Ramos Chrcanovic; Mauro Henrique Nogueira Guimarães Abreu
Journal:  Oral Maxillofac Surg       Date:  2012-05-06

Review 2.  Interventions for replacing missing teeth: dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla.

Authors:  Marco Esposito; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-09-05

Review 3.  Full arch rehabilitation in patients with atrophic upper jaws with zygomatic implants: a systematic review.

Authors:  Ana Helena Pereira Gracher; Marcos Boaventura de Moura; Patrícia da Silva Peres; Geninho Thomé; Luís Eduardo Marques Padovan; Larissa Carvalho Trojan
Journal:  Int J Implant Dent       Date:  2021-02-26

4.  Platform switch hybrid zygoma implants improve prosthetics and marginal bone protection after extra-sinus placement.

Authors:  Paweł Aleksandrowicz; Marta Kusa-Podkańska; Witold Tomkiewicz; Lidia Kotuła; Jan Perek; Joanna Wysokińska-Miszczuk
Journal:  Clin Implant Dent Relat Res       Date:  2020-02-11       Impact factor: 3.932