Literature DB >> 20467603

Bone augmentation versus 5-mm dental implants in posterior atrophic jaws. Four-month post-loading results from a randomised controlled clinical trial.

Pietro Felice1, Vittorio Checchi, Roberto Pistilli, Antonio Scarano, Gerardo Pellegrino, Marco Esposito.   

Abstract

PURPOSE: To evaluate whether short (5 mm) dental implants could be a suitable alternative to augmentation and placement of longer implants (10 mm) in posterior atrophic jaws.
MATERIALS AND METHODS: Thirty partially edentulous patients with bilateral posterior edentulism were included: 15 patients having 5 to 7 mm of residual crestal height above the mandibular canal, and 15 patients having 4 to 6 mm of residual crestal height below the maxillary sinus and bone thickness of at least 8 mm measured on a CT scan. The patients were randomised either to receive one to three submerged 5-mm-long Rescue implants (Megagen) or 10-mm-long implants placed in augmented bone according to a split-mouth design. Mandibles were augmented with interpositional anorganic bovine bone blocks (Bio-Oss) and maxillae with granular Bio-Oss placed through a lateral window under the lifted sinus membrane. Resorbable barriers were used to cover the grafted sites. Grafts were left to heal for 4 months before placing the implants using a submerged technique. Four months after implant placement, provisional reinforced acrylic prostheses were delivered and replaced 4 months later by definitive screw-retained metal-ceramic prostheses. Outcome measures were: prosthesis and implant failures, any complications, time needed to fully recover mental nerve function (only for mandibular implants) and patient preference assessed 1 month after loading. All patients were followed up to delivery of the final restorations (4 months after loading).
RESULTS: A systematic deviation from the research protocol occurred: the operator used another implant system (EZ Plus, Megagen) for implants 10 mm or longer with a diameter of 4 mm at the augmented sites. No patients dropped out. In 5 patients of the augmented group (all mandibles), there was not enough height to place 10-mm-long implants as planned and shorter implants (7 and 8.5 mm) were used instead. In each group, one prosthesis could not be placed when planned because an implant was found to be mobile at abutment connection: one 5 mm maxillary implant and one 8.5 mm mandibular implant in the augmented group. Five complications occurred: two in the augmented group (one maxillary sinus perforation and one mandibular wound dehiscence after implant placement possibly associated with the failure of one implant) versus three maxillary sinus perforations in the 5-mm-long implant group. The difference was not statistically significant. No patient suffered from permanent disruption of alveolar inferior nerve function, however, significantly more patients had paraesthesia for up to 3 days in the augmented group. There was no statistically significant difference in patient preference with the majority of patients expressing no preference for which treatment they received, finding both of them acceptable.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20467603

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  8 in total

1.  Short implants: A systematic review.

Authors:  I Karthikeyan; Shrikar R Desai; Rika Singh
Journal:  J Indian Soc Periodontol       Date:  2012-07

Review 2.  Systematic Review and Meta-Analysis on Incidence of Altered Sensation of Mandibular Implant Surgery.

Authors:  Chia-Shu Lin; Shih-Yun Wu; Hsin-Yi Huang; Yu-Lin Lai
Journal:  PLoS One       Date:  2016-04-21       Impact factor: 3.240

3.  Vertical bone regeneration using rhBMP-2 and VEGF.

Authors:  Lara Schorn; Christoph Sproll; Michelle Ommerborn; Christian Naujoks; Norbert R Kübler; Rita Depprich
Journal:  Head Face Med       Date:  2017-06-07       Impact factor: 2.151

Review 4.  Treatment concepts for the posterior maxilla and mandible: short implants versus long implants in augmented bone.

Authors:  Daniel Stefan Thoma; Jae-Kook Cha; Ui-Won Jung
Journal:  J Periodontal Implant Sci       Date:  2017-02-28       Impact factor: 2.614

Review 5.  Prosthetic Rehabilitation of the Partially Edentulous Atrophic Posterior Mandible with Short Implants (≤ 8 mm) Compared with the Sandwich Osteotomy and Delayed Placement of Standard Length Implants (> 8 mm): a Systematic Review.

Authors:  Thomas Starch-Jensen; Helle Baungaard Nielsen
Journal:  J Oral Maxillofac Res       Date:  2018-06-29

6.  The rehabilitation of posterior atrophic maxilla by using the graftless option of short implant versus conventional long implant with sinus graft: A systematic review and meta-analysis of randomized controlled clinical trial.

Authors:  Sachin Haribhau Chaware; Vrushali Thakare; Ritu Chaudhary; Ajit Jankar; Smruti Thakkar; Sidesh Borse
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

7.  Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height.

Authors:  Hae-Young Kim; Jin-Yong Yang; Bo-Yoon Chung; Jeong Chan Kim; In-Sung Yeo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

8.  A New Transalveolar Sinus Lift Procedure for Single Implant Placement: The Ebanist Technique. A Technical Description and Case Series.

Authors:  Rosario Rizzo; Vittorio Checchi; Federico Marsili; Antonio Zani; Serena Incerti-Parenti; Luigi Checchi
Journal:  Open Dent J       Date:  2017-03-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.