Abstract
Midazolam in an autoinjector was evaluated in an open-label dose escalation study involving 39 healthy participants. Safety and pharmacokinetic parameters were determined for doses ranging from 5 to 30 mg. No serious adverse events were noted during the study. Two participants (30 mg) experienced changes in their electrocardiogram (trigeminy and prolongation of QRS complex) that met the criteria for dose-limiting adverse events. No significant respiratory depression was noted during the study. The midazolam doses studied exhibited a median t(max) of 0.5 hours with a geometric mean terminal elimination half-life value of 4.1 hours (range, 2.9-4.5 hours). The extent of systemic exposure, assessed by area under the curve (AUC) and maximum concentration (C(max)), tended to increase proportionally with increasing doses from 5 to 30 mg; however, for the male 30-mg group, there was evidence of a larger than proportional increase in AUC.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20466872 DOI: 10.1177/0091270009358083