Literature DB >> 20466234

Relation between pulse oximetry plethysmographic waveform amplitude induced by passive leg raising and cardiac index in spontaneously breathing subjects.

Samuel Delerme1, Samuel Castro, Yonathan Freund, Pierre Nazeyrollas, Marie-Odile Josse, Béatrice Madonna-Py, Edwin Rouff, Bruno Riou, Patrick Ray.   

Abstract

INTRODUCTION: Previous studies suggested that variation of pulse oximetric plethysmographic (POP) waveform amplitude (Delta POP) could predict fluid responsiveness in mechanically ventilated patients. Our objective was to correlate the variations of Delta POP and the variations of cardiac index (CI) induced by passive leg raising (PLR) in spontaneously breathing volunteers.
METHODS: We studied 26 spontaneously breathing volunteers using a pulse oximeter attached to the middle finger. We assessed hemodynamic variables, including Delta POP (%) (POP(max) - POP(min))/[(POP(max) + POP(min))/2] and CI determined by transthoracic echocardiography at baseline (eg, semirecumbent position), during PLR at 60 degrees, and back to baseline.
RESULTS: Cardiac index significantly increased from 2.2 to 2.5 L/min x m(2) (P < .01) at 60 degrees PLR. Conversely, Delta POP significantly decreased from 22% to 15% (P < .01) at 60 degrees PLR. There was a weak correlation between CI and Delta POP variations at 60 degrees PLR (r = 0.40; P < .01). The area under curve of the receiver operating characteristic curve for Delta POP as a predictor of an increase of CI of 15% was not significant (0.67 +/- 0.10; P = .16).
CONCLUSION: The variation of Delta POP induced by PLR is not an accurate predictor of increase in CI. (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20466234     DOI: 10.1016/j.ajem.2009.03.023

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  9 in total

Review 1.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

Review 2.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Crit Care Clin       Date:  2015-01       Impact factor: 3.598

3.  Critically ill patients in emergency department may be characterized by low amplitude and high variability of amplitude of pulse photoplethysmography.

Authors:  Jussi Pirneskoski; Veli-Pekka Harjola; Petri Jeskanen; Lari Linnamurto; Simo Saikko; Jouni Nurmi
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-06-24       Impact factor: 2.953

4.  Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients.

Authors:  Matthieu Biais; Vincent Cottenceau; Laurent Petit; Françoise Masson; Jean-François Cochard; François Sztark
Journal:  Crit Care       Date:  2011-07-12       Impact factor: 9.097

5.  The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

Authors:  Tom Peachey; Andrew Tang; Elinor C Baker; Jason Pott; Yonathan Freund; Tim Harris
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-02       Impact factor: 2.953

Review 6.  The haemodynamic dilemma in emergency care: Is fluid responsiveness the answer? A systematic review.

Authors:  Mohammed H Elwan; Ashraf Roshdy; Eman M Elsharkawy; Salah M Eltahan; Timothy J Coats
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2017-03-06       Impact factor: 2.953

7.  Respiratory variations in pulse pressure and photoplethysmographic waveform amplitude during positive expiratory pressure and continuous positive airway pressure in a model of progressive hypovolemia.

Authors:  Ingrid Elise Hoff; Jonny Hisdal; Svein Aslak Landsverk; Jo Røislien; Knut Arvid Kirkebøen; Lars Øivind Høiseth
Journal:  PLoS One       Date:  2019-09-27       Impact factor: 3.240

8.  Increasing signal processing sophistication in the calculation of the respiratory modulation of the photoplethysmogram (DPOP).

Authors:  Paul S Addison; Rui Wang; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-09-11       Impact factor: 2.502

9.  Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion.

Authors:  Paul S Addison; Rui Wang; Scott J McGonigle; Alberto A Uribe; Sergio D Bergese
Journal:  Anesthesiol Res Pract       Date:  2014-08-07
  9 in total