Method for estimating the intensity of scattered radiation using a scatter generation model.

M Honda1, K Kikuchi, K Komatsu.   

Abstract

An analytical formula for estimating the intensity of scattered radiation in an x-ray image under various exposure conditions has been developed. The formula was derived using measured data of scatter and primary intensity for various exposure conditions. To simplify the formula, a scatter generation model was constructed mathematically which assumes that the scattered fluence in a material depends on three processes: (1) scattering of the primary photons; (2) scattering of previously scattered photons; and (3) attenuation of the scattered photons. Using this model, the dependence of scatter-to-primary ratio on phantom thickness and the tube voltage was expressed by a simple equation. Parameters included in the model were determined from the analysis of measured data. Based on empirical data, it was assumed that the dependence of scatter-to-primary ratio on air gap and field size is not affected by variations of phantom thickness and tube voltage. The final formula, which does not include the term of phantom thickness, gives an estimate of the intensity of the scattered radiation from exposure conditions. The scatter intensity estimated using the formula was compared with measured data for various phantom thicknesses, tube voltages, air gaps, and field sizes; the results show that the intensity of scattered radiation can be estimated within about +/- 10% using predetermined parameters.

Mesh:

Year:  1991        PMID: 2046608     DOI: 10.1118/1.596710

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

2.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  An Accurate Scatter Measurement and Correction Technique for Cone Beam Breast CT Imaging Using Scanning Sampled Measurement (SSM) Technique.

Authors:  Xinming Liu; Chris C Shaw; Tianpeng Wang; Lingyun Chen; Mustafa C Altunbas; S Cheenu Kappadath
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-02-28

4.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Scatter correction method for x-ray CT using primary modulation: phantom studies.

Authors:  Hewei Gao; Rebecca Fahrig; N Robert Bennett; Mingshan Sun; Josh Star-Lack; Lei Zhu
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

6.  Experimental separation of diagnostic X-ray spectra into scatter and primary components.

Authors:  H Kubota; Y Ozaki; M Matsumoto; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.