Literature DB >> 20465880

Using a distal access catheter in acute stroke intervention with penumbra, merci and gateway. A technical case report.

J S Kalia1, O O Zaidat.   

Abstract

SUMMARY: This technical report describes the successful use of the newly introduced Distal Access Catheter, initially designed to work with the Merci Retrieval System with the Penumbra aspiration system as the main aspiration catheter. Both devices, one a clot retriever and the other a thrombo-aspiration device, can be used and deployed via the same catheter saving time during acute stoke intervention. Moreover, the larger inner diameter of the distal access catheter may allow more effective clot aspiration.

Entities:  

Year:  2009        PMID: 20465880      PMCID: PMC3299428          DOI: 10.1177/159101990901500408

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  4 in total

1.  Time is brain--quantified.

Authors:  Jeffrey L Saver
Journal:  Stroke       Date:  2005-12-08       Impact factor: 7.914

2.  Intracranial placement of a new, compliant guide catheter: technical note.

Authors:  Min S Park; Michael F Stiefel; David Fiorella; Michael Kelly; Cameron G McDougall; Felipe C Albuquerque
Journal:  Neurosurgery       Date:  2008-09       Impact factor: 4.654

3.  Thrombolysis with alteplase 3 to 4.5 hours after acute ischemic stroke.

Authors:  Werner Hacke; Markku Kaste; Erich Bluhmki; Miroslav Brozman; Antoni Dávalos; Donata Guidetti; Vincent Larrue; Kennedy R Lees; Zakaria Medeghri; Thomas Machnig; Dietmar Schneider; Rüdiger von Kummer; Nils Wahlgren; Danilo Toni
Journal:  N Engl J Med       Date:  2008-09-25       Impact factor: 91.245

4.  Mechanical thrombectomy for acute ischemic stroke: final results of the Multi MERCI trial.

Authors:  Wade S Smith; Gene Sung; Jeffrey Saver; Ronald Budzik; Gary Duckwiler; David S Liebeskind; Helmi L Lutsep; Marilyn M Rymer; Randall T Higashida; Sidney Starkman; Y Pierre Gobin; Donald Frei; Thomas Grobelny; Frank Hellinger; Dan Huddle; Chelsea Kidwell; Walter Koroshetz; Michael Marks; Gary Nesbit; Isaac E Silverman
Journal:  Stroke       Date:  2008-02-28       Impact factor: 7.914

  4 in total
  4 in total

1.  Impact of Merci device fracture on clinical outcome of acute ischemic stroke after mechanical thrombectomy.

Authors:  Zhong-Song Shi; Gary R Duckwiler; Yince Loh; David S Liebeskind; Nestor R Gonzalez; Satoshi Tateshima; Reza Jahan; Jeffrey L Saver; Fernando Viñuela
Journal:  CNS Neurosci Ther       Date:  2012-08-20       Impact factor: 5.243

2.  Mechanical thrombectomy with the penumbra 3D separator and lesional aspiration: technical feasibility and clinical outcome.

Authors:  A Mpotsaris; M Bussmeyer; W Weber
Journal:  Clin Neuroradiol       Date:  2013-07-28       Impact factor: 3.649

3.  Optimal Guiding Catheter Length for Endovascular Coiling of Intracranial Aneurysms in Anterior Circulation in Era of Flourishing Distal Access System.

Authors:  Zhen Yu Jia; Sang Hun Lee; Young Eun Kim; Joon Ho Choi; Sun Moon Hwang; Ga Young Lee; Jin Ho Youn; Deok Hee Lee
Journal:  Neurointervention       Date:  2017-09-05

Review 4.  Reperfusion therapy in acute ischemic stroke: dawn of a new era?

Authors:  Sonu Bhaskar; Peter Stanwell; Dennis Cordato; John Attia; Christopher Levi
Journal:  BMC Neurol       Date:  2018-01-16       Impact factor: 2.474

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.