Literature DB >> 2045947

Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study.

M Ljungberg1, S E Strand.   

Abstract

Single-photon emission computed tomography (SPECT) is important for imaging radioactivity distributions in vivo. Quantitative SPECT is limited due to attenuation and scatter contribution. Approximations such as constant attenuation and mono-exponential scatter functions will not be valid for non-homogeneous regions. A correction method is described where non-uniform density-maps are used in the attenuation correction. Correction for non-uniform scatter is made by a convolution technique based on scatter line-spread functions (SLSF) calculated for different locations inside a clinically realistic, nonhomogeneous, computer phantom. Calculations have been made for a myocardiac source, a uniform source in the lungs and a tumor located in the lungs. Projections were simulated for photon energies corresponding to 201Tl, 99mTc, and 111In. The results show that quantitative images can be obtained in nonhomogeneous regions. An increased contrast has also been demonstrated in the SLSF-corrected images. Comparison with measurements have been made to validate the Monte Carlo code and the scatter and attenuation method.

Entities:  

Mesh:

Year:  1991        PMID: 2045947

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  14 in total

1.  Quantitative single photon emission tomography: verification for sources in an elliptical water phantom.

Authors:  M H Ljungberg; M A King; S E Strand
Journal:  Eur J Nucl Med       Date:  1992

2.  Accelerated SPECT Monte Carlo Simulation Using Multiple Projection Sampling and Convolution-Based Forced Detection.

Authors:  Shaoying Liu; Michael A King; Aaron B Brill; Michael G Stabin; Troy H Farncombe
Journal:  IEEE Trans Nucl Sci       Date:  2008-01-01       Impact factor: 1.679

3.  Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-14       Impact factor: 9.236

Review 4.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 5.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

6.  A non-negative fast multiplicative algorithm in 3D scatter-compensated SPET reconstruction.

Authors:  S H Walrand; L R van Elmbt; S Pauwels
Journal:  Eur J Nucl Med       Date:  1996-11

Review 7.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

8.  Attenuation correction of (111)In planar images by use of dual energy, fundamental study by Monte Carlo simulation.

Authors:  Seiji Shirakawa; Masanori Tadokoro; Hiroshi Hashimoto; Tomoya Ushiroda; Hiroshi Toyama
Journal:  Radiol Phys Technol       Date:  2014-08-23

Review 9.  Three-dimensional imaging-based radiobiological dosimetry.

Authors:  George Sgouros; Eric Frey; Richard Wahl; Bin He; Andrew Prideaux; Robert Hobbs
Journal:  Semin Nucl Med       Date:  2008-09       Impact factor: 4.446

10.  A detector response function design in pinhole SPECT including geometrical calibration.

Authors:  Z El Bitar; R H Huesman; R Boutchko; Virgile Bekaert; David Brasse; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-03-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.