Literature DB >> 20459259

Optical coherence tomography with online visualization of more than seven rendered volumes per second.

Joachim Probst1, Dierck Hillmann, Eva Lankenau, Christan Winter, Stefan Oelckers, Peter Koch, Gereon Hüttmann.   

Abstract

Nearly real-time visualization of 3-D volumes is crucial for the use of optical coherence tomography (OCT) during microsurgery. With an ultrahigh speed spectral domain OCT coupled to a surgical microscope, on-line display of 7.2 rendered volumes at 87 megapixels per second is demonstrated. Calculating the A-scans from the spectra is done on a quad-core personal computer (PC), while dedicated software for the 3-D rendering is executed on a high performance video card. Imaging speed is practically only limited by the readout of the camera. First experiments show the feasibility of real-time 3-D OCT for guided interventions.

Mesh:

Year:  2010        PMID: 20459259     DOI: 10.1117/1.3314898

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  15 in total

1.  [Advances in endoscopic diagnosis of dysplasia and carcinoma of the larynx].

Authors:  C Arens; U Vorwerk; T Just; C S Betz; M Kraft
Journal:  HNO       Date:  2012-01       Impact factor: 1.284

2.  Master slave en-face OCT/SLO.

Authors:  Adrian Bradu; Konstantin Kapinchev; Frederick Barnes; Adrian Podoleanu
Journal:  Biomed Opt Express       Date:  2015-08-27       Impact factor: 3.732

3.  Imaging the eye fundus with real-time en-face spectral domain optical coherence tomography.

Authors:  Adrian Bradu; Adrian Gh Podoleanu
Journal:  Biomed Opt Express       Date:  2014-03-19       Impact factor: 3.732

4.  High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s.

Authors:  Wolfgang Wieser; Wolfgang Draxinger; Thomas Klein; Sebastian Karpf; Tom Pfeiffer; Robert Huber
Journal:  Biomed Opt Express       Date:  2014-08-06       Impact factor: 3.732

Review 5.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

6.  Review of intraoperative optical coherence tomography: technology and applications [Invited].

Authors:  Oscar M Carrasco-Zevallos; Christian Viehland; Brenton Keller; Mark Draelos; Anthony N Kuo; Cynthia A Toth; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

7.  Real-time visualization and interaction with static and live optical coherence tomography volumes in immersive virtual reality.

Authors:  Mark Draelos; Brenton Keller; Christian Viehland; Oscar M Carrasco-Zevallos; Anthony Kuo; Joseph Izatt
Journal:  Biomed Opt Express       Date:  2018-05-30       Impact factor: 3.732

8.  Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

Authors:  Chen D Lu; Nadia K Waheed; Andre Witkin; Caroline R Baumal; Jonathan J Liu; Benjamin Potsaid; Anthony Joseph; Vijaysekhar Jayaraman; Alex Cable; Kinpui Chan; Jay S Duker; James G Fujimoto
Journal:  Ophthalmic Surg Lasers Imaging Retina       Date:  2018-02-01       Impact factor: 1.300

9.  Comprehensive review of surgical microscopes: technology development and medical applications.

Authors:  Ling Ma; Baowei Fei
Journal:  J Biomed Opt       Date:  2021-01       Impact factor: 3.170

10.  Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second.

Authors:  Dong-Hak Choi; Hideaki Hiro-Oka; Kimiya Shimizu; Kohji Ohbayashi
Journal:  Biomed Opt Express       Date:  2012-11-01       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.