Time-resolved DPIV investigation of pulsatile flow in symmetric stenotic arteries--effects of phase angle.

Satyaprakash Karri1, Pavlos P Vlachos.   

Abstract

The effect of phase angle between pressure and flow waveforms on the flow characteristics in stenosed compliant vessels for coronary (phase angle (PA) of approximately -225 deg) and peripheral flows (PA of approximately -45 deg) is investigated using time resolved digital particle image velocimetry. Synthetic arteries with 50% and 75% stenosis at various physiological conditions with Reynolds numbers (Re) of 250, 350, and 450 and corresponding Womersley parameter (alpha) of 2.7, 3.2, and 3.7 were studied; wall-shear stresses (WSSs), oscillatory shear index (OSI), and recirculation lengths were determined. Additionally, flow transitional characteristics were examined using power spectral density (PSD), wavenumber spectra, and turbulence statistics of the axial velocity component. It is observed that the coronary flow conditions exhibit lower wall-shear stresses and larger recirculation lengths compared with peripheral flows. Mean peak shear stresses can be as high as 150 dyn/cm(2) and 92 dyn/cm(2) for peripheral and coronary flows, respectively, with 50% stenosis at Re=450 and alpha=3.7. These values can be as high as 590 dyn/cm(2) and 490 dyn/cm(2), respectively, for the same conditions with 75% stenosis. The OSI is close to 0.5 near the reattachment point indicating fluctuating WSS over the entire cardiac cycle for both 50% and 75% stenosis. For 50% stenosis, the OSI fluctuated at various locations over the length of the vessel indicating several regions of recirculation in contrast to a distinct recirculation region observed for 75% stenosis. PSD plots across various cross-sections along the length of the vessel and wavenumber spectra along the centerline indicate that turbulence occurs only for 75% stenosis. For coronary flows, the streamwise locations where the flow transitions to turbulence and relaminarizes are approximately one diameter upstream compared with peripheral flows indicating that coronary flows are more susceptible to turbulence.

Entities:  

Mesh:

Year:  2010        PMID: 20459198     DOI: 10.1115/1.4000934

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

1.  Microfluidic measurement for blood flow and platelet adhesion around a stenotic channel: Effects of tile size on the detection of platelet adhesion in a correlation map.

Authors:  Sung Yong Jung; Eunseop Yeom
Journal:  Biomicrofluidics       Date:  2017-04-25       Impact factor: 2.800

2.  In vivo measurement of blood flow in a micro-scale stenosis model generated by laser photothermal blood coagulation.

Authors:  Sang Joon Lee; Ho Jin Ha
Journal:  IET Syst Biol       Date:  2013-04       Impact factor: 1.615

3.  Fluid-dynamic optimal design of helical vascular graft for stenotic disturbed flow.

Authors:  Hojin Ha; Dongha Hwang; Woo-Rak Choi; Jehyun Baek; Sang Joon Lee
Journal:  PLoS One       Date:  2014-10-31       Impact factor: 3.240

4.  Characteristics of pulsatile flows in curved stenosed channels.

Authors:  Hyeonji Hong; Eunseop Yeom; Ho Seong Ji; Hyun Dong Kim; Kyung Chun Kim
Journal:  PLoS One       Date:  2017-10-19       Impact factor: 3.240

5.  Variations in pulsatile flow around stenosed microchannel depending on viscosity.

Authors:  Hyeonji Hong; Jae Min Song; Eunseop Yeom
Journal:  PLoS One       Date:  2019-01-24       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.