Literature DB >> 20457099

Evaluation of amylase testing as a tool for saliva screening of crime scene trace swabs.

Johannes Hedman1, Erik Dalin, Birgitta Rasmusson, Ricky Ansell.   

Abstract

Amylase testing has been used as a presumptive test for crime scene saliva for over three decades, mainly to locate saliva stains on surfaces. We have developed a saliva screening application for crime scene trace swabs, utilising an amylase sensitive paper (Phadebas(®) Forensic Press test). Positive results were obtained for all tested dried saliva stains (0.5-32 μL) with high or intermediate amylase activity (840 and 290 kU/L). Results were typically obtained within 5 min, and all samples that produced DNA profiles were positive. However, salivary amylase activities, as well as DNA concentrations, vary significantly between individuals. We show that there is no correlation between amylase activity and amount of DNA in fresh saliva. Even so, a positive amylase result indicates presence of saliva, and thereby presence of DNA. Amylase testing may be useful for screening in investigations where the number of DNA analyses is limited due to cost, e.g., in volume crime.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Mesh:

Substances:

Year:  2010        PMID: 20457099     DOI: 10.1016/j.fsigen.2010.03.003

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  5 in total

1.  mRNA profiling using a minimum of five mRNA markers per body fluid and a novel scoring method for body fluid identification.

Authors:  Amy D Roeder; Cordula Haas
Journal:  Int J Legal Med       Date:  2012-12-20       Impact factor: 2.686

2.  Sensitivity and specificity of presumptive tests for blood, saliva and semen.

Authors:  Marielle Vennemann; Georgina Scott; Lynn Curran; Felix Bittner; Shanan S Tobe
Journal:  Forensic Sci Med Pathol       Date:  2014-01-18       Impact factor: 2.007

3.  DNA persistence of bite marks on food and its relevance for STR typing.

Authors:  Céline M Pfeifer; Anja Gass; Rachel Klein-Unseld; Peter Wiegand
Journal:  Int J Legal Med       Date:  2017-06-26       Impact factor: 2.686

4.  Mapping Aerosolized Saliva on Face Coverings for Biosensing Applications.

Authors:  Zhicheng Jin; Alec Jorns; Wonjun Yim; Ryan Wing; Yash Mantri; Jiajing Zhou; Jingcheng Zhou; Zhuohong Wu; Colman Moore; William F Penny; Jesse V Jokerst
Journal:  Anal Chem       Date:  2021-07-26       Impact factor: 8.008

5.  Blood and saliva contamination on protective eyewear during dental treatment.

Authors:  Nora Bergmann; Isabell Lindörfer; Michelle Alicia Ommerborn
Journal:  Clin Oral Investig       Date:  2022-02-14       Impact factor: 3.606

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.