The impact of overscan on patient dose with first generation multislice CT scanners.

Ioannis A Tsalafoutas1.   

Abstract

Helical scanning requires the irradiation of larger lengths than those planned. This is referred to as overscan and results to an increase of patient dose. Its impact on patient dose was investigated for three first generation multislice CT scanners; a six-, a quad- and a dual-slice. The amount of overscan was determined using the scanners' dose-length product (DLP) indications and films positioned on the CT table. With the preset protocol for the chest examination selected in all CT scanners, the overscan length calculated from the DLP indications was 6.3, 3.5 and 2cm respectively, whereas the corresponding figures derived from the films were 6.6, 4.8 and 2.5 to 3.2cm. For a 30cm scan length, the respective contributions of overscan to the DLP values were 17, 10 and 6%, whereas for a scan length of 20cm the respective values increased to 24, 15 and 9%. For the smallest scan lengths allowed in helical mode, the respective contributions reached 53, 88 and 67% because for the six-slice scanner the smallest scan length was limited to twice the collimation, whereas in the quad and dual scanners no limitation existed. For small scan lengths the presence of overscan cancels out any dose reduction offered by helical scanning with pitch factor values larger than one and therefore the axial mode should be preferred, when this is not prohibited by the diagnostic task in question.
Copyright © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20456992     DOI: 10.1016/j.ejmp.2010.03.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  Patient centring and scan length: how inaccurate practice impacts on radiation dose in CT colonography (CTC).

Authors:  Sergio Salerno; Giuseppe Lo Re; Davide Bellini; Marco Rengo; Maurizio Marrale; Maria Chiara Terranova; Laura Scopelliti; Andrea Laghi
Journal:  Radiol Med       Date:  2019-03-08       Impact factor: 3.469

2.  Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection.

Authors:  Samuel J Weisenthal; Les Folio; William Kovacs; Ari Seff; Vana Derderian; Ronald M Summers; Jianhua Yao
Journal:  J Digit Imaging       Date:  2016-08       Impact factor: 4.056

3.  Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner.

Authors:  Ronald Booij; Marcel L Dijkshoorn; Marcel van Straten
Journal:  Eur Radiol       Date:  2017-01-26       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.