Literature DB >> 20456032

Opaque layer firing temperature and aging effect on the flexural strength of ceramic fused to cobalt-chromium alloy.

Luis Gustavo Oliveira de Vasconcellos1, Leonardo Buso, Geraldo H L Lombardo, Rodrigo O A Souza, Lafayette Nogueira, Marco Antonio Bottino, Mutlu Ozcan.   

Abstract

PURPOSE: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength.
MATERIALS AND METHODS: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mum) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Säckingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey's test (alpha= 0.05).
RESULTS: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p= 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted.
CONCLUSION: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20456032     DOI: 10.1111/j.1532-849X.2010.00600.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy.

Authors:  Klaus-Peter Krug; Andreas W Knauber; Frank P Nothdurft
Journal:  Clin Oral Investig       Date:  2014-03-26       Impact factor: 3.573

2.  Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.

Authors:  Myung-Joo Kim; Yun-Jung Choi; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak
Journal:  Materials (Basel)       Date:  2017-01-23       Impact factor: 3.623

3.  Effect of SiC Abrasive Blasting Parameters on the Quality of the Ceramic and Ni-Cr Dental Alloy Joint.

Authors:  Emilia Wołowiec-Korecka; Weronika Czepułkowska-Pawlak; Zofia Kula; Leszek Klimek
Journal:  Materials (Basel)       Date:  2022-01-26       Impact factor: 3.623

4.  Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses.

Authors:  Halil İbrahim Kılınç; Bülent Kesim; Hasan Önder Gümüş; Mehmet Dinçel; Selçuk Erkaya
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

5.  Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy.

Authors:  Yoshito Minesaki; Sadaaki Murahara; Yutaro Kajihara; Yoshihisa Takenouchi; Takuo Tanaka; Shiro Suzuki; Hiroyuki Minami
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

6.  Evaluation of Bond Strength of Pressed and Layered Veneering Ceramics to Nickel-Chromium Alloy.

Authors:  Mitra Farzin; Amir Alireza Khaledi; Behnam Malekpour; Mohammad Hassan Naseri
Journal:  J Dent (Shiraz)       Date:  2015-09
  6 in total