Literature DB >> 20453766

Computed tomography identification of latent pseudoaneurysm after blunt splenic injury: pathology or technology?

Jordan A Weinberg1, Mark E Lockhart, Abhishek D Parmar, Russell L Griffin, Sherry M Melton, Marianne J Vandromme, Gerald McGwin, Loring W Rue.   

Abstract

BACKGROUND: Serial computed tomography (CT) imaging of blunt splenic injury can identify the latent formation of splenic artery pseudoaneurysms (PSAs), potentially contributing to improved success in nonoperative management. However, it remains unclear whether the delayed appearance of such PSAs is truly pathophysiologic or attributable to imaging quality and timing. The objective of this study was to evaluate the influence of recent advancements in imaging technology on the incidence of the latent PSA.
METHODS: Consecutive patients with blunt splenic injury over 4.5 years were identified from our trauma registry. Follow-up CT was performed for all but low-grade injuries 24 hours to 48 hours after initial CT. Incidences of both early and latent PSA formation were reviewed and compared with respect to imaging technology (4-slice vs. >or=16-slice).
RESULTS: A total of 411 patients were selected for nonoperative management of blunt splenic injury. Of these, 135 had imaging performed with 4-slice CT, and 276 had imaging performed with CTs of >=16-slice. Mean follow-up was 75 days (range, 1-1178 days) and 362 patients (88%) had follow-up beyond 7 days. Comparing 4-slice CT with >or=16-slice CT, there were no significant differences in the incidence of early PSA (3.7% vs. 4.7%; p = 0.91) or latent PSA (2.2% vs. 2.9%; p = 0.90). In both groups, latent PSAs accounted for approximately 38% of all PSAs observed. Splenic injury grade on initial CT was not associated with latent PSA (p = 0.54). Overall, the failure rate of nonoperative management was 7.3%. Overall mortality was 4.6%. No mortalities were related to splenic or other intra-abdominal injury.
CONCLUSIONS: The incidences of both early and latent PSA have remained remarkably stable despite advances in CT technology. This suggests that latent PSA is not a result of imaging technique but perhaps a true pathophysiologic phenomenon. Injury grade is unhelpful concerning the prediction of latent PSA formation.

Entities:  

Mesh:

Year:  2010        PMID: 20453766     DOI: 10.1097/TA.0b013e3181d769fc

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  5 in total

Review 1.  Contrast-enhanced ultrasound of blunt abdominal trauma in children.

Authors:  Harriet J Paltiel; Richard A Barth; Costanza Bruno; Aaron E Chen; Annamaria Deganello; Zoltan Harkanyi; M Katherine Henry; Damjana Ključevšek; Susan J Back
Journal:  Pediatr Radiol       Date:  2021-05-12

Review 2.  Value of repeat CT for nonoperative management of patients with blunt liver and spleen injury: a systematic review.

Authors:  Khadidja Malloum Boukar; Lynne Moore; Pier-Alexandre Tardif; Kahina Soltana; Natalie Yanchar; John Kortbeek; Howard Champion; Julien Clement
Journal:  Eur J Trauma Emerg Surg       Date:  2021-01-23       Impact factor: 3.693

3.  The song remains the same although the instruments are changing: complications following selective non-operative management of blunt spleen trauma: a retrospective review of patients at a level I trauma centre from 1996 to 2007.

Authors:  Aisling A Clancy; Corina Tiruta; Dianne Ashman; Chad G Ball; Andrew W Kirkpatrick
Journal:  J Trauma Manag Outcomes       Date:  2012-03-13

4.  Can we predict delayed undesirable events after blunt injury to the torso visceral organs?

Authors:  Kenichiro Uchida; Yasumitsu Mizobata; Naohiro Hagawa; Tomonori Yamamoto; Shinichiro Kaga; Tomohiro Noda; Naoki Shinyama; Tetsuro Nishimura; Hiromasa Yamamoto
Journal:  Acute Med Surg       Date:  2018-01-30

Review 5.  A rare case of non-traumatic intrasplenic pseudoaneurysms in a patient with acute T-cell lymphoblastic leukemia.

Authors:  Margherita Trinci; Carlo Giangregorio; Giovanna Calabrese; Pierfrancesco Ottaviani; Pascale Riu; Michele Galluzzo; Vittorio Miele
Journal:  J Ultrasound       Date:  2019-08-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.