Literature DB >> 20451788

Effect of saliva contamination on bracket failure with a self-etching primer: a prospective controlled clinical trial.

María D Campoy1, Eliseo Plasencia, Ascensión Vicente, Luis A Bravo, Rosa Cibrián.   

Abstract

INTRODUCTION: The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif).
METHODS: This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both groups, saliva was applied in a split-mouth design. Diagonally opposite quadrants were allocated to either the contaminated group (contamination before [153 teeth] or after [115 teeth] TSEP application) or to the uncontaminated control group (263 teeth). Recording of failed brackets involved only first-time failures, and the observation period was a minimum of 6 months.
RESULTS: The chi-squared test showed no significant differences (P = 0.11) in bracket failures between the groups. Kaplan-Meier survival analysis detected no significant differences in the survival rates between the 3 groups (P = 0.51). Most bond failures occurred during the first 3 months. In all 3 groups, the adhesive remaining on teeth after debonding tended to be less than half.
CONCLUSIONS: These findings suggest that saliva contamination before or after application of self-etching primer does not increase the clinical risk of bond failure. Copyright (c) 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20451788     DOI: 10.1016/j.ajodo.2008.06.032

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Shear bond strength of rebonded brackets after removal of adhesives with Er,Cr:YSGG laser.

Authors:  Katsuyuki Ishida; Toshiya Endo; Koichi Shinkai; Yoshiroh Katoh
Journal:  Odontology       Date:  2011-05-07       Impact factor: 2.634

2.  Effect of moisture, saliva, and blood contamination on the shear bond strength of brackets bonded with a conventional bonding system and self-etched bonding system.

Authors:  Mandava Prasad; Shamil Mohamed; Krishna Nayak; Sharath Kumar Shetty; Ashok Kumar Talapaneni
Journal:  J Nat Sci Biol Med       Date:  2014-01

3.  Effect of saliva contamination on cementation of orthodontic brackets using different adhesive systems.

Authors:  Aliden-Willian Robaski; Saulo Pamato; Marcelo Tomás-de Oliveira; Jefferson-Ricardo Pereira
Journal:  J Clin Exp Dent       Date:  2017-07-01

4.  Comparative evaluation of sealing ability, penetration and adaptation of a self etching pit and fissure sealant- stereomicroscopic and scanning electron microscopic analyses.

Authors:  Dhruv Garg; Karuna Mahabala; Amita Lewis; Srikant Natarajan; Anupama Nayak; Ashwin Rao
Journal:  J Clin Exp Dent       Date:  2019-06-01

5.  A Clinical Comparison of Failure Rates of Metallic and Ceramic Brackets: A Twelve-Month Study.

Authors:  Tomasz Ogiński; Beata Kawala; Marcin Mikulewicz; Joanna Antoszewska-Smith
Journal:  Biomed Res Int       Date:  2020-01-10       Impact factor: 3.411

6.  Microleakage of a Self-Adhesive Flowable Composite, a Self-Adhesive Fissure Sealant and a Conventional Fissure Sealant in Permanent Teeth with/without Saliva Contamination.

Authors:  Zohre Sadat Hosseinipour; Alireza Heidari; Mehdi Shahrabi; Kiana Poorzandpoush
Journal:  Front Dent       Date:  2019-08-30

Review 7.  Incidence of orthodontic brackets detachment during orthodontic treatment: A systematic review.

Authors:  Naif Almosa; Hamayun Zafar
Journal:  Pak J Med Sci       Date:  2018 May-Jun       Impact factor: 1.088

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.