Literature DB >> 20448336

Mechanical properties and motion of the cupula of the human semicircular canal.

Pierre Selva1, Charles M Oman, Howard A Stone.   

Abstract

The mathematical model for the dynamics of the cupula-endolymph system of the inner ear semicircular canal, as elaborated by numerous investigators, remains a foundational tool in all of vestibular physiology. Most models represent the cupula as a linear spring-like element of stiffness K=DeltaP/DeltaV, where DeltaV is the volume displaced upon application of a pressure difference DeltaP. The parameter K directly influences the long time constant of the cupula-endolymph system. Given estimates of K based on experiments, we use thick and thin bending membrane theory, and also finite-element simulations based on more realistic cupula morphologies, to estimate the human cupula's Young's modulus E approximately 5.4 Pa. We show that for a model morphology, thick bending membrane theory and finite-element predictions are in good agreement, and conclude that the morphology of the attachment of the cupula to the slope of the crista should not greatly influence the volume displacement. We note, however, that other biological materials with very low E are hydrogels that have significant viscoelastic properties. Experiments to directly measure E and investigate potential viscoelastic behavior ultimately may be needed. In addition, based on experimental images we study two other different shapes for the cupula and quantify their impact on the deflection of the cupula. We also use a three-dimensional finite-element model to analyze both the shear strain distribution and its time evolution near the sensory epithelium. We conclude that stimulation of sensory hair cells probably begins at the centre of the crista and spreads toward the periphery of the cupula and down the sides of the crista. Thus, spatio-temporal variations in the shearing stimulus are predicted to impact subsequent transduction and encoding. Finally, modeling the fluid-filled vertical channels believed to lie within the cupula, we investigate the impact of different tube diameters on the transverse displacement field. We show that, for the assumed diameters and grid spacing, cupula displacements should be highly sensitive to the diameter of the tubes. Experiments to verify the existence of cupular channels and accurately measure their diameter and spacing are needed.

Entities:  

Mesh:

Year:  2009        PMID: 20448336     DOI: 10.3233/VES-2009-0359

Source DB:  PubMed          Journal:  J Vestib Res        ISSN: 0957-4271            Impact factor:   2.435


  5 in total

1.  Experimental measurement of utricle system dynamic response to inertial stimulus.

Authors:  M D Dunlap; J W Grant
Journal:  J Assoc Res Otolaryngol       Date:  2014-05-21

2.  Development of Bionic Semicircular Canals and the Sensation of Angular Acceleration.

Authors:  Zhi Wang; Shien Lu; Xianjin Wang; Yuhang Chen; Junjie Gong; Yani Jiang; Yixiang Bian
Journal:  Bioengineering (Basel)       Date:  2022-04-20

3.  Assessing morphology and function of the semicircular duct system: introducing new in-situ visualization and software toolbox.

Authors:  R David; A Stoessel; A Berthoz; F Spoor; D Bennequin
Journal:  Sci Rep       Date:  2016-09-08       Impact factor: 4.379

4.  Exploiting decellularized cochleae as scaffolds for inner ear tissue engineering.

Authors:  Adam J Mellott; Heather E Shinogle; Jennifer G Nelson-Brantley; Michael S Detamore; Hinrich Staecker
Journal:  Stem Cell Res Ther       Date:  2017-02-28       Impact factor: 6.832

5.  Exploring the biomechanical responses of human cupula by numerical analysis of temperature experiments.

Authors:  Xiang Wu; Shen Yu; Shuang Shen; Wenlong Liu
Journal:  Sci Rep       Date:  2021-04-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.