Literature DB >> 20447199

Comparison of ultraflex and niti-s stents for palliation of unresectable malignant gastroduodenal obstruction.

Iruru Maetani1, Takeo Ukita, Tomoko Nambu, Hiroaki Shigoka, Shigefumi Omuta, Takuro Endo, Kei Takahashi.   

Abstract

AIM: Self-expandable metallic stents are widely used for palliation of malignant gastric outlet obstruction (GOO), but clinical outcomes of different stents have not been compared. Here, we compared outcomes in patients with a GOO receiving either an Ultraflex (UF) or a Niti-S (NS) stent.
METHODS: Prospective outcomes in 53 patients receiving palliative placement of an NS stent for symptomatic GOO over a 3-year period were compared with those obtained retrospectively in 31 patients receiving a UF stent in a previous 5-year period. Main outcome measurement was between-group comparison of clinical outcome, complications, and reintervention.
RESULTS: Baseline characteristics between the groups were comparable. No difference in technical or clinical success rate was observed. Median procedure time for NS placement was shorter than for UF (15 vs 40 min; P < 0.0001). Complications were more frequent with NS than with UF placement, albeit without statistical significance (16% vs 25%). Although two severe complications occurred in each group, neither was stent related in the NS group. Reintervention was more frequent in the NS group (3% vs 21%; P = 0.0485). Median survival time was 53 versus 88 days for UF versus NS stents, respectively.
CONCLUSION: Although no significant difference was seen with regard to feasibility, reintervention was less frequent with UF stents than with NS stents. However, UF stents require much more procedure time, and a complicated and difficult placement procedure. These observations suggest that although NS stents placed using a through-the-scope technique may be more patient friendly than UF stents, further optimization of through-the-scope stents is still required. Further prospective comparison of NS and UF stents in GOO treatment is warranted.

Entities:  

Mesh:

Year:  2010        PMID: 20447199     DOI: 10.1111/j.1443-1661.2010.00942.x

Source DB:  PubMed          Journal:  Dig Endosc        ISSN: 0915-5635            Impact factor:   7.559


  6 in total

Review 1.  Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

Authors:  Emo E van Halsema; Erik A J Rauws; Paul Fockens; Jeanin E van Hooft
Journal:  World J Gastroenterol       Date:  2015-11-21       Impact factor: 5.742

2.  Endoscopic management of unresectable malignant gastroduodenal obstruction with a nitinol uncovered metal stent: A prospective Japanese multicenter study.

Authors:  Reina Sasaki; Yuji Sakai; Toshio Tsuyuguchi; Takao Nishikawa; Tatsuya Fujimoto; Shigeru Mikami; Harutoshi Sugiyama; Osamu Yokosuka
Journal:  World J Gastroenterol       Date:  2016-04-14       Impact factor: 5.742

3.  Covered metallic stents with an anti-migration design vs. uncovered stents for the palliation of malignant gastric outlet obstruction: a multicenter, randomized trial.

Authors:  Hyuk Lee; Byung-Hoon Min; Jeong Hoon Lee; Cheol Min Shin; Younjoo Kim; Hyunsoo Chung; Sang Hyub Lee
Journal:  Am J Gastroenterol       Date:  2015-09-15       Impact factor: 10.864

Review 4.  How to successfully administer palliative treatment with a stent for malignant gastric outlet obstruction?

Authors:  Iruru Maetani
Journal:  Front Med (Lausanne)       Date:  2022-08-09

Review 5.  Endoscopic ultrasound-guided double stenting for biliary and duodenal obstruction.

Authors:  Takao Itoi; Fumihide Itokawa; Atsushi Sofuni; Toshio Kurihara; Kentaro Ishii; Shujiro Tsuji; Nobuhito Ikeuchi; Junko Umeda; Rena Tanaka; Ryosuke Tonozuka; Fuminori Moriyasu
Journal:  Endosc Ultrasound       Date:  2012-04       Impact factor: 5.628

Review 6.  Malignant gastric outlet obstruction: Which is the best therapeutic option?

Authors:  Edoardo Troncone; Alessandro Fugazza; Annalisa Cappello; Giovanna Del Vecchio Blanco; Giovanni Monteleone; Alessandro Repici; Anthony Yuen Bun Teoh; Andrea Anderloni
Journal:  World J Gastroenterol       Date:  2020-04-28       Impact factor: 5.742

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.