Literature DB >> 20447094

Understanding the mechanism of the water drinking test: the role of fluid challenge volume in patients with medically controlled primary open angle glaucoma.

Nathan M Kerr1, Helen V Danesh-Meyer.   

Abstract

BACKGROUND: To determine whether a 500-mL fluid challenge produces a different intraocular pressure (IOP) response profile compared with a 1000-mL water drinking test (WDT).
METHODS: Prospective, observer-masked, cross-over, observational study. Patients with primary open angle glaucoma were recruited from a private specialist glaucoma practice. One eye of each patient was included. Subjects were randomized to receive either a 500-mL or 1000-mL fluid challenge. Baseline IOP was recorded with a Goldmann applanation tonometer and then every 15 min for 1 h. A second WDT with the alternate volume of water was performed after a minimum washout period of 24 h. Primary statistical analysis was performed using a two-way anova repeated measures of variance with a Bonferroni post-hoc test.
RESULTS: Fifteen patients were included in this study. The mean patient age was 67.0 +/- 10.2 (SD) years, and 60% of patients were female. There was no statistically significant difference in baseline IOP between the 500-mL and 1000-mL WDTs (P = 0.11). Both fluid challenge volumes produced a statistically significant rise in IOP from baseline at 15, 30 and 45 min after water ingestion. However the mean maximum increase in IOP was less in the 500-mL WDT (3.3 +/- 1.8 mmHg [23.9%]) compared with the 1000-mL WDT (4.9 +/- 2.3 mmHg [32.5%]; P = 0.0095).
CONCLUSION: The 500-mL WDT may provide an alternative for patients who are unable to tolerate drinking 1000 mL of water. However, because the maximum IOP obtained is less, a 500-mL WDT cannot be used to directly estimate peak diurnal pressure.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20447094     DOI: 10.1111/j.1442-9071.2009.02183.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  5 in total

1.  Correlation between intraocular pressure obtained with water drinking test versus modified diurnal tension curve measurement in pseudoexfoliation glaucoma.

Authors:  Penpe Gül Firat; Seyhan Dikci; İlknur Tuncer Firat; Soner Demirel; Murat Firat; Emrah Öztürk; Zarife Ekici Gök
Journal:  Int Ophthalmol       Date:  2021-04-20       Impact factor: 2.031

2.  Intraocular pressure dynamics with prostaglandin analogs: a clinical application of the water-drinking test.

Authors:  Pelin Özyol; Erhan Özyol; Ercan Baldemir
Journal:  Clin Ophthalmol       Date:  2016-07-22

3.  Intraocular pressure fluctuation after water drinking test in primary angle-closure glaucoma and primary open-angle glaucoma.

Authors:  Yi-Chieh Poon; Mei-Ching Teng; Pei-Wen Lin; Jen-Chia Tsai; Ing-Chou Lai
Journal:  Indian J Ophthalmol       Date:  2016-12       Impact factor: 1.848

4.  Water Drinking Test: Intraocular Pressure Changes after Tube Surgery and Trabeculectomy.

Authors:  Mohammad Reza Razeghinejad; Zahra Tajbakhsh; Mohammad Hossein Nowroozzadeh; Masoumeh Masoumpour
Journal:  J Ophthalmic Vis Res       Date:  2017 Oct-Dec

5.  The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor.

Authors:  Banu Bozkurt; Nilsel Okudan; Muaz Belviranli; Ayse Bozkurt Oflaz
Journal:  Indian J Ophthalmol       Date:  2019-01       Impact factor: 1.848

  5 in total