| Literature DB >> 20444590 |
Yu Zhou1, Yuanyuan Zhang, Fengguang Pan, Yansong Li, Shiying Lu, Honglin Ren, Qingfeng Shen, Zhaohui Li, Junhui Zhang, Qijun Chen, Zengshan Liu.
Abstract
Mercury ions (Hg(2+)) are one of the most dangerous pollutants. Even at low concentration, it causes serious environmental and health problems. Current methods for the detection of Hg(2+) in environmental samples are tedious and time consuming because they require sophisticated instrumentation and complicated sample pre-treatment processes. In this work, a novel probe with high selectivity towards Hg(2+) was synthesized and a one step competitive immunochromatographic assay based on the probe for the detection of Hg(2+) was developed and applied for water samples. The detection conjugate was immobilized on one end of the nitrocellulose membrane (detection line) and anti-BSA polyclonal antibody was immobilized on the other end of the membrane (control line). Hg(2+) in samples competed with the probe to bind with immobilized detection conjugate. The visual detection limit of Hg(2+) in spiked water samples was found to be about 1 ppb. The qualitative assay can be performed within 15 min. The advantages of the technique are rapidity, low cost and without the need of any equipment and complicated sample preparation. Copyright (c) 2010 Elsevier B.V. All rights reserved.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20444590 DOI: 10.1016/j.bios.2010.04.003