Literature DB >> 20443508

Intensity modulated radiotherapy of non-small-cell lung cancer incorporating SPECT ventilation imaging.

Iram Munawar1, Brian P Yaremko, Jeff Craig, Michael Oliver, Stewart Gaede, George Rodrigues, Edward Yu, Robert Henderson Reid, Eugene Leung, Jean-Luc Urbain, Jeff Chen, Eugene Wong.   

Abstract

PURPOSE: The authors performed this retrospective study to investigate the impact of using ventilation scans obtained from single photon emission computed tomography (SPECT) in selecting beam directions in intensity modulated radiation therapy (IMRT) planning in lung cancer radiotherapy to spare dosimetrically well ventilated lung.
METHODS: For ten consecutive stage III non-small-cell lung cancer patients, the authors obtained both ventilation/perfusion SPECT scans and four-dimensional CT scans for treatment planning purposes. Each ventilation scan was registered with the corresponding planning CT and ventilation volumes corresponding to either > or = 50% (vv50) or > or = 70% (vv70) of the maximum SPECT count were automatically segmented. For each patient, three IMRT plans were generated: One using nine equally spaced beams optimized according to nonfunctional lung based mean lung dose and lung v20; a second using nine equally spaced beams optimized to avoid vv50 and vv70; and a third plan using only three beams with gantry angles chosen based on minimum mean ventilated lung dose calculated for each conformal beam at every 10 degrees gantry angle avoiding vv50 and vv70. Resultant dose volume histogram indices were calculated for each plan and were compared with respect to calculated SPECT-based ventilation parameters in order to quantify the potential utility of ventilation SPECT in this setting.
RESULTS: Two patient groups were identified based on (i) the overlap volume between PTV and vv50 and (ii) the average angular mean ventilated lung dose (AAMvLD). The first parameter quantifies the proximity of the PTV to well ventilated lung and the second parameter quantifies the degree of ventilation that surrounds the PTV. For group 1 patients, < or = 5% of the vv50 overlapped with the PTV. For group 2 patients, > 5% of the vv50 overlapped the PTV. Group 1 was further classified into subgroups 1A and 1B: For subgroup 1A, AAMvLD is >18 Gy, implying that the functional lung surrounds the PTV; for subgroup 1B, AAMvLD is <18 Gy, implying that the well ventilated lung does not completely surround PTV. For subgroup 1A, the plans generated using ventilated lung avoidance reduced dose to vv50 and vv70, with below tolerance dose to normal lung and acceptable coverage of the PTV. For subgroup 1B, the dose to the total lung and well ventilated lung are reduced with the beam direction optimization for the three-beam plan. For group 2, there was no significant dosimetric advantage of using SPECT-based ventilation information in IMRT plan optimization.
CONCLUSIONS: In conclusion, it is feasible to use SPECT ventilation scans to optimize IMRT beam direction and, subsequently, to reduce dose to ventilated lung when overlap of the PTV and the ventilated lung is minimal and that the PTV is not surrounded by the ventilated lung. The potential benefit of ventilation SPECT scanning can be determined by preplanning assessment of overlap volumes and the AAMvLD.

Entities:  

Mesh:

Year:  2010        PMID: 20443508     DOI: 10.1118/1.3358128

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

Review 1.  Imaging techniques for tumour delineation and heterogeneity quantification of lung cancer: overview of current possibilities.

Authors:  Wouter van Elmpt; Catharina M L Zegers; Marco Das; Dirk De Ruysscher
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

2.  Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Leah Schubert; Quentin Diot; Timothy Waxweiller; Phillip Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Chad Rusthoven; Laurie Gaspar; Brian Kavanagh; Moyed Miften
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-15       Impact factor: 7.038

3.  Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy.

Authors:  Austin M Faught; Yuya Miyasaka; Noriyuki Kadoya; Richard Castillo; Edward Castillo; Yevgeniy Vinogradskiy; Tokihiro Yamamoto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-04-26       Impact factor: 7.038

Review 4.  Functional and molecular image guidance in radiotherapy treatment planning optimization.

Authors:  Shiva K Das; Randall K Ten Haken
Journal:  Semin Radiat Oncol       Date:  2011-04       Impact factor: 5.934

5.  Semiquantification and classification of local pulmonary function by V/Q single photon emission computed tomography in patients with non-small cell lung cancer: potential indication for radiotherapy planning.

Authors:  Shuanghu Tiger Yuan; Kirk A Frey; Milton D Gross; James A Hayman; Doug Arenberg; Jeffrey L Curtis; Xu-Wei Cai; Nithya Ramnath; Gregory P Kalemkerian; Randall K Ten Haken; Avraham Eisbruch; Feng-Ming Spring Kong
Journal:  J Thorac Oncol       Date:  2011-01       Impact factor: 15.609

6.  A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

Authors:  H H Zhang; S Gao; W Chen; L Shi; W D D'Souza; R R Meyer
Journal:  Phys Med Biol       Date:  2013-03-21       Impact factor: 3.609

7.  Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Chad G Rusthoven; Leah Schubert; Bernard Jones; Austin Faught; Richard Castillo; Edward Castillo; Laurie E Gaspar; Jennifer Kwak; Timothy Waxweiler; Michele Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Thomas Guerrero; Inga Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-18       Impact factor: 7.038

8.  Use of 4-dimensional computed tomography-based ventilation imaging to correlate lung dose and function with clinical outcomes.

Authors:  Yevgeniy Vinogradskiy; Richard Castillo; Edward Castillo; Susan L Tucker; Zhongxing Liao; Thomas Guerrero; Mary K Martel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-03-06       Impact factor: 7.038

9.  Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study.

Authors:  Yevgeniy Vinogradskiy; Phillip J Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-01       Impact factor: 7.038

10.  Accounting for respiratory motion in small serial structures during radiotherapy planning: proof of concept in virtual bronchoscopy-guided lung functional avoidance radiotherapy.

Authors:  Esther Vicente; Arezoo Modiri; Kun-Chang Yu; Henky Wibowo; Yulong Yan; Robert Timmerman; Amit Sawant
Journal:  Phys Med Biol       Date:  2019-11-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.