Internal fixation of femoral neck fractures. A comparative biomechanical study of Knowles pins and 6.5-mm cancellous screws.

E R Springer1, P F Lachiewicz, J A Gilbert.   

Abstract

In a comparative biomechanical study of the stability of experimentally produced femoral neck fractures fixed with Knowles pins or with 6.5-mm cancellous screws, 12 matched pairs of anatomic specimen femurs were divided into four groups of standardized osteotomies. One member of each matched pair was fixed with three or four 6.5-mm cancellous screws, whereas the other member was fixed with the same number of Knowles pins. Mechanical testing was performed on an Instron testing machine. There was no statistically significant difference in maximum load to failure or in fixed stiffness between the two methods of fixation. When examining maximum load to failure, three of either device provided fixation equivalent to four. Although there was a difference in absolute fixed stiffness between specimens fixed with three Knowles pins compared to four, when stiffness was expressed as a percentage of intact stiffness, there was no difference between any fixation group. From an analysis of the observed modes of failure and from calculations of the flexural rigidity provided by the devices, it is proposed that the quality of the trabecular bone of the femoral neck is a major factor in the experimental fixation of femoral neck fractures.

Entities:  

Mesh:

Year:  1991        PMID: 2044298

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture.

Authors:  Zheng Wang; Yong Yang; Gangning Feng; Haohui Guo; Zhirong Chen; Yaogeng Chen; Qunhua Jin
Journal:  Biomed Eng Online       Date:  2022-06-10       Impact factor: 3.903

2.  Breakage of Knowles pins used for femoral neck fractures.

Authors:  J A Lozano Requena; T Bas Hermida; C Perez Belmonte; A J Llabres; F Baixauli
Journal:  Int Orthop       Date:  1993-12       Impact factor: 3.075

3.  [Research progress in treatment of femoral neck fracture in the elderly].

Authors:  Yangyang Zhou; Yingjie Ni; Xingjuan Li; Hui Chen; Yunfeng Rui
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-08-15

4.  Does Screw Location Affect the Risk of Subtrochanteric Femur Fracture After Femoral Neck Fixation? A Biomechanical Study.

Authors:  Erica K Crump; Michael Quacinella; Bradley K Deafenbaugh
Journal:  Clin Orthop Relat Res       Date:  2020-04       Impact factor: 4.755