Literature DB >> 20442099

Safety and efficacy of UltraShape Contour I treatments to improve the appearance of body contours: multiple treatments in shorter intervals.

Benjamin Ascher1.   

Abstract

BACKGROUND: The UltraShape Contour I System (CE 0344; UltraShape Ltd., Yoqneam, Israel) is a noninvasive fat reduction and body contouring system currently approved for use outside the United States that utilizes focused ultrasound to selectively disrupt adipocytes.
OBJECTIVE: To evaluate the clinical safety and efficacy of the Contour I system when the intervals between treatments are shortened.
METHODS: Twenty-five healthy Caucasian women were selected from the patient population at two clinics in Paris, France, and received three 30- to 90-minute Contour I treatments in the abdominal region at two-week intervals. Safety parameters evaluated included adverse events, local skin reaction, and pain. Efficacy parameters evaluated included treatment area circumference, body weight, and comparison of before and after photos. Untreated thigh areas served as an internal control. Subjects were followed for 84 days after the last treatment (day 112).
RESULTS: No adverse events occurred. The majority of subjects (n = 23; approximately 90%) reported no pain. Mean midline circumference (2 cm below midline) was reduced by 2.47 cm (P < .001) on day 14 after the first Contour I treatment, 3.51 cm (P < .001) on day 56, and 3.58 cm (P < .001) on day 112. Peak midline circumference reduction was 3.12 cm on day 112. Most patients (n = 14; 63%) reported a positive change in body contour. Mean thigh circumference (the control area) was unchanged; the relative change between treated and untreated areas of the abdomen was significantly different at all time points. Circumference and weight reduction were significantly correlated (r = 0.42-0.71) at all time points; mean weight decrease was not statistically significant. Circumference reduction on day 112 positively correlated with patients' subjective satisfaction scores.
CONCLUSIONS: Our data showed that successive Contour I treatments at two-week intervals were safe and tolerable and also significantly reduced treatment area circumference.

Entities:  

Mesh:

Year:  2010        PMID: 20442099     DOI: 10.1177/1090820X09360692

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  12 in total

Review 1.  [Physical lipolysis].

Authors:  M Steinert
Journal:  Hautarzt       Date:  2010-10       Impact factor: 0.751

2.  Long-term follow-up for noninvasive body contouring treatment in Asians.

Authors:  Shyue-Luen Chang; Yau-Li Huang; Mei-Ching Lee; Chih-Hsiang Chang; Ying-Fang Lin; Chun Yu Cheng; Sindy Hu
Journal:  Lasers Med Sci       Date:  2015-12-29       Impact factor: 3.161

3.  A Six-week Low-level Laser Therapy Protocol is Effective for Reducing Waist, Hip, Thigh, and Upper Abdomen Circumference.

Authors:  Carl R Thornfeldt; Paul M Thaxton; Carl S Hornfeldt
Journal:  J Clin Aesthet Dermatol       Date:  2016-06-01

4.  Combination therapy of focused ultrasound and radio-frequency for noninvasive body contouring in Asians with MRI photographic documentation.

Authors:  Shyue-Luen Chang; Yau-Li Huang; Mei-Ching Lee; Chih-Hsiang Chang; Wen-Hung Chung; En-Haw Wu; Sindy Hu
Journal:  Lasers Med Sci       Date:  2013-03-24       Impact factor: 3.161

5.  Nonthermal Pulsed Ultrasound Treatment for the Reduction in Abdominal Fat: A Pilot Study.

Authors:  Mara Weinstein Velez; Omer Ibrahim; Kathleen Petrell; Jeffrey S Dover
Journal:  J Clin Aesthet Dermatol       Date:  2018-09-01

Review 6.  Israeli Innovations in the Field of Plastic Surgery.

Authors:  Lior Har-Shai; Sar-El Ofek; Stav Cohen; Keren H Cohen; Dafna Shilo Yaacobi; Asaf Olshinka; Rami P Dibbs; Dean D Ad-El
Journal:  Semin Plast Surg       Date:  2022-05-26       Impact factor: 2.195

Review 7.  [Body contouring].

Authors:  N Krüger; S Lübberding; G Sattler
Journal:  Hautarzt       Date:  2015-10       Impact factor: 0.751

8.  Experimental evaluation of high intensity focused ultrasound for fat reduction of ex vivo porcine adipose tissue.

Authors:  Antria Filippou; Christakis Damianou
Journal:  J Ultrasound       Date:  2022-02-01

9.  Histological and Ultrastructural Effects of Ultrasound-induced Cavitation on Human Skin Adipose Tissue.

Authors:  Daniele Bani; Alessandro Quattrini Li; Giancarlo Freschi; Giulia Lo Russo
Journal:  Plast Reconstr Surg Glob Open       Date:  2013-10-07

10.  Intralipotherapy, the State of the Art.

Authors:  Roberto Amore; Hernán Pinto; Kostas Gritzalas; Carlota Hernández; Katarzyna Skwara-Guzikowska; Domenico Amuso; Vincenza Leonardi
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-10-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.