Interstitial thermal ablation with a fast rotating dual-mode transducer.

Guillaume Bouchoux1, Neil Owen, Francoise Chavrier, Rémi Berriet, Gérard Fleury, Jean-Yves Chapelon, Cyril Lafon.   

Abstract

Interstitial ultrasound applicators can be a minimally invasive alternative for treating targets that are unresectable or are inaccessible by extracorporeal methods. Dual-mode transducers for ultrasound imaging and therapy were developed to address the constraints of a miniaturized applicator and real-time treatment monitoring. We propose an original treatment strategy that combines ultrasound imaging and therapy using a dual-mode transducer rotating at 8 revolutions per second. Real-time B-mode imaging was interrupted to emit high-intensity ultrasound over a selected therapy aperture. A full 360 degrees image was taken every 8th rotation to image the therapy aperture. Numerical simulations were performed to study the effect of rotation on tissue heating, and to study the effect of the treatment sequence on transducer temperature. With the time-averaged transducer surface intensity held at 12 W/cm(2) to maintain transducer temperature below 66 degrees C, higher field intensities and deeper lesions were produced by narrower therapy apertures. A prototype system was built and tested using in vitro samples of porcine liver. Lesions up to 8 mm were produced using a time-averaged transducer surface intensity of 12 W/cm(2) applied for a period of 240 s over a therapy aperture of 40 degrees. Apparent strain imaging of the therapy aperture improved the contrast between treated and spared tissues, which could not be differentiated on B-mode images. With appropriate limits on the transducer output, real-time imaging and deep thermal ablation are feasible and sustainable using a rotating dual-mode transducer.

Mesh:

Year:  2010        PMID: 20442018     DOI: 10.1109/TUFFC.2010.1520

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  2 in total

1.  Dual-mode IVUS transducer for image-guided brain therapy: preliminary experiments.

Authors:  Carl D Herickhoff; Christy M Wilson; Gerald A Grant; Gavin W Britz; Edward D Light; Mark L Palmeri; Patrick D Wolf; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2011-08-19       Impact factor: 2.998

Review 2.  Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.

Authors:  Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2015-03-23       Impact factor: 3.914

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.