Literature DB >> 20441891

The influence of external factors on the operational stability of the biosensor response.

Olga Stikoniene1, Feliksas Ivanauskas, Valdas Laurinavicius.   

Abstract

The behaviour of the electrochemical glucose biosensor based on the glucose oxidase was examined in the diffusion and the kinetic modes of the action. The sensitivity and linearity of the biosensor can be monitored changing the permeability of the outer membrane of the biosensor. The mathematical model based on the enzymatic conversion of the substrate and the diffusion of the substrate was created. The influence of the fluctuations of the membrane thickness, the diffusion coefficients and pH were modelled and their impact was evaluated at different modes of an action of the biosensor. Taking into account that limited acceptable fluctuations of the biosensor response should not exceed 5%, we calculated how K(M(app.)) and V(max) can move to satisfy this requirement. In a deep diffusive mode (thick highly acetylated membrane), the fluctuations of K(M(app.)) up to 400% do not influence significantly the biosensor response. In the diffusion mode of action of the biosensor, the limit of the V(max) fluctuations is on the level of 34%. The increase of the thickness of the membrane 5 times, increases the limit of fluctuations only to 19%. The reduction of the permeability of the membrane 4 times increases the level of limited fluctuations about 10-16%. The novelty of this work is binding into one system the fluctuations of pH and diffusion parameters and demonstrating the interdependence of them as an integrated factor of the reliability of the biosensor response.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20441891     DOI: 10.1016/j.talanta.2010.02.016

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Effect of diffusion limitations on multianalyte determination from biased biosensor response.

Authors:  Romas Baronas; Juozas Kulys; Algirdas Lančinskas; Antanas Zilinskas
Journal:  Sensors (Basel)       Date:  2014-03-07       Impact factor: 3.576

2.  Modeling microelectrode biosensors: free-flow calibration can substantially underestimate tissue concentrations.

Authors:  Adam J H Newton; Mark J Wall; Magnus J E Richardson
Journal:  J Neurophysiol       Date:  2016-12-07       Impact factor: 2.714

3.  Rapid determination of kappa-carrageenan using a biosensor from immobilized Pseudomonas carrageenovora cells.

Authors:  Riyadh Abdulmalek Hassan; Lee Yook Heng; Asmat Ahmad; Ling Ling Tan
Journal:  PLoS One       Date:  2019-04-16       Impact factor: 3.240

4.  A large response range reflectometric urea biosensor made from silica-gel nanoparticles.

Authors:  Muawia Alqasaimeh; Lee Yook Heng; Musa Ahmad; A S Santhana Raj; Tan Ling Ling
Journal:  Sensors (Basel)       Date:  2014-07-22       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.