Literature DB >> 20438354

Adhesion of endodontic sealers to human root dentine submitted to different surface treatments.

Gisele Aihara Haragushiku1, Manoel D Sousa-Neto, Yara T C Silva-Sousa, Edson Alfredo, Silvio Correa Silva, Ricardo Gariba Silva.   

Abstract

OBJECTIVE: To evaluate the adhesion of the endodontic sealers Epiphany, Apexit Plus, and AH Plus to root canal dentin submitted to different surface treatments, by using the push-out test.
METHODS: One hundred twenty-eight root cylinders obtained from maxillary canines were embedded in acrylic resin, had the canals prepared, and were randomly assigned to four groups (n = 32), according to root dentin treatment: (I) distilled water (control), (II) 17% EDTAC, (III) 1% NaOCl and (IV) Er:YAG laser with 16-Hz, 400-mJ input (240-mJ output) and 0.32-J/cm(2) energy density. Each group was divided into four subgroups (n = 8) filled with Epiphany (either dispensed from the automix syringe supplied by the manufacturer or prepared by hand mixing), Apexit Plus, or AH Plus. Data (MPa) were analyzed by ANOVA and Tukey's test.
RESULTS: A statistically significant difference (p < 0.01) was found among the root-canal sealers, except for the Epiphany subgroups, which had statistically similar results to each other (p > 0.01): AH Plus (4.77 +/- 0.85), Epiphany/hand mixed (3.06 +/- 1.34), Epiphany/automix syringe (2.68 +/- 1.35), and Apexit Plus (1.22 +/- 0.33). A significant difference (p < 0.01) was found among the dentin surface treatments. The highest adhesion values were obtained with AH Plus when root dentin was treated with Er:YAG laser and 17% EDTAC. Epiphany sealer presented the lowest adhesion values to root dentin treated with 17% EDTAC.
CONCLUSIONS: The resin-based sealers had different adhesive behaviors, depending on the treatment of root canal walls. The mode of preparation of Epiphany (automix syringe or hand mixing) did not influence sealer adhesion to root dentin.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20438354     DOI: 10.1089/pho.2008.2474

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  5 in total

1.  The Effect of Increased Temperatures of QMix and EDTA on the Push-out Bond Strength of an Epoxy-resin Based Sealer.

Authors:  Emel Uzunoglu; Sevinc Aktemur Turker; Sevilay Karahan
Journal:  J Clin Diagn Res       Date:  2015-07-01

2.  Effect of advanced irrigation protocols on self-expanding Smart-Seal obturation system: A scanning electron microscopic push-out bond strength study.

Authors:  Vibha Hegde; Shashank Arora
Journal:  Contemp Clin Dent       Date:  2015 Jan-Mar

3.  Effect of root dentin conditioning using different chelating agents on pushout bond strength of MTA-fillapex and bioroot RCS: An in vitro study.

Authors:  Jesline Maria Jose; E M Manju Krishna; S Maneesh Ahamed; Robin Theruvil; Jain Mathew; Saira George
Journal:  J Conserv Dent       Date:  2021-10-09

4.  Intratubular penetration capacity of HiFlow bioceramic sealer used with warm obturation techniques and single cone: A confocal laser scanning microscopic study.

Authors:  Alberto Casino Alegre; Susana Aranda Verdú; José Ignacio Zarzosa López; Eliseo Plasencia Alcina; Jorge Rubio Climent; Antonio Pallarés Sabater
Journal:  Heliyon       Date:  2022-08-27

Review 5.  In vivo Biocompatibility and Bioactivity of Calcium Silicate-Based Bioceramics in Endodontics.

Authors:  Wencheng Song; Wei Sun; Lili Chen; Zhenglin Yuan
Journal:  Front Bioeng Biotechnol       Date:  2020-10-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.