Effects of improper source coupling in frequency-domain near-infrared spectroscopy.

T E J Noponen1, K Kotilahti, I Nissilä, T Kajava, P T Meriläinen.   

Abstract

Currently, there is no widely used method to assess the reliability of contact between optodes and tissue in near-infrared spectroscopy (NIRS). In this study we observe a high linear dependence (R(2) approximately 0.99) of the logarithmic modulation amplitude (ln(I(AC))), average intensity (ln(I(DC))) and phase (phi) on the source-detector distance (SDD) ranging from approximately 20 to 50 mm on human forehead measurements. The regression of phi is clearly reduced in measurements where light leakage occurs, mainly due to insufficient contact between the source optode and tissue. Utilizing this observation, a novel criterion to detect light leakage is developed. The criterion is applied to study the reliability of hemodynamic responses measured on the human forehead when breathing carbon dioxide-enriched air and during hyperventilation. The contrast of the signals is significantly lower in measurements which were adversely affected by light leakage. Furthermore, such unreliable signals at SDDs >or= 50 mm correlate significantly (for [HbO2] p < 0.01 and for [HbR] p < 0.001) better with the signals measured at SDDs < 20 mm. Using this method, poor contact between the source optode and tissue can be detected and corrected before the actual measurement, which enables us to avoid the acquisition of low contrast cortical signals.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20436234     DOI: 10.1088/0031-9155/55/10/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Implicit and explicit prior information in near-infrared spectral imaging: accuracy, quantification and diagnostic value.

Authors:  Brian W Pogue; Scott C Davis; Frederic Leblond; Michael A Mastanduno; Hamid Dehghani; Keith D Paulsen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

2.  Impaired cerebral vasoreactivity may cause cerebral blood volume dip following obstructive sleep apnea termination.

Authors:  Jaakko Virtanen; Tommi Noponen; Tapani Salmi; Jussi Toppila; Pekka Meriläinen
Journal:  Sleep Breath       Date:  2011-05-10       Impact factor: 2.816

3.  Compliant head probe for positioning electroencephalography electrodes and near-infrared spectroscopy optodes.

Authors:  Paolo Giacometti; Solomon G Diamond
Journal:  J Biomed Opt       Date:  2013-02       Impact factor: 3.170

Review 4.  Shining a Light on Awareness: A Review of Functional Near-Infrared Spectroscopy for Prolonged Disorders of Consciousness.

Authors:  Mohammed Rupawala; Hamid Dehghani; Samuel J E Lucas; Peter Tino; Damian Cruse
Journal:  Front Neurol       Date:  2018-05-22       Impact factor: 4.003

5.  Movement artefact removal from NIRS signal using multi-channel IMU data.

Authors:  Masudur R Siddiquee; J Sebastian Marquez; Roozbeh Atri; Rodrigo Ramon; Robin Perry Mayrand; Ou Bai
Journal:  Biomed Eng Online       Date:  2018-09-10       Impact factor: 2.819