Literature DB >> 2043581

Quality of vision through diffractive bifocal intraocular lenses.

J L Jay1, H S Chakrabarti, J D Morrison.   

Abstract

Two elderly women have each received a monofocal intraocular lens in one eye and a 3M diffractive bifocal intraocular lens in the other eye. Both eyes were shown to have equivalent retinal/neural function by measuring contrast sensitivity to laser interference fringes which bypassed refractive and other defects of the ocular media. The eyes with a bifocal intraocular lens displayed a much greater depth of focus, though at the expense of diminished contrast sensitivity compared with the normal values expected for that age. Simulation experiments suggested that the observed reduction in contrast sensitivity was not adequately explained by a simple reduction in retinal illumination of the in-focus image as might intuitively be expected from the bifocal separation of incident light to two simultaneous focal points. The simultaneous superimposition of the out-of-focus image on the in-focus image must also be considered, since this caused a significant reduction in contrast sensitivity when the retinal illumination was insufficiently above the photopic luminance threshold.

Entities:  

Mesh:

Year:  1991        PMID: 2043581      PMCID: PMC1042384          DOI: 10.1136/bjo.75.6.359

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  Prospective study of the new diffractive bifocal intraocular lens.

Authors:  S P Percival
Journal:  Eye (Lond)       Date:  1989       Impact factor: 3.775

2.  Contrast sensitivity in patients with a new type of multifocal intraocular lens.

Authors:  T Olsen; L Corydon
Journal:  J Cataract Refract Surg       Date:  1990-01       Impact factor: 3.351

3.  Assessment of the optical contributions to the age-related deterioration in vision.

Authors:  J D Morrison; C McGrath
Journal:  Q J Exp Physiol       Date:  1985-04

4.  Photographic simulation of image quality through bifocal intraocular lenses.

Authors:  H C Zisser; D L Guyton
Journal:  Am J Ophthalmol       Date:  1989-09-15       Impact factor: 5.258

5.  Colour perception in pseudophakia.

Authors:  J L Jay; V B Gautam; D Allan
Journal:  Br J Ophthalmol       Date:  1982-10       Impact factor: 4.638

6.  The effects of age on spatial frequency perception in human subjects.

Authors:  C McGrath; J D Morrison
Journal:  Q J Exp Physiol       Date:  1981-07

7.  Optical and retinal factors affecting visual resolution.

Authors:  F W Campbell; D G Green
Journal:  J Physiol       Date:  1965-12       Impact factor: 5.182

8.  The effects of a single intramuscular injection of atropine sulphate on visual performance in man.

Authors:  C D Kay; J D Morrison
Journal:  Hum Toxicol       Date:  1987-03
  8 in total
  2 in total

1.  Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation.

Authors:  G Prakash; D R Prakash; A Agarwal; D A Kumar; A Agarwal; S Jacob
Journal:  Eye (Lond)       Date:  2011-06-17       Impact factor: 3.775

2.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.