Literature DB >> 20435151

Sensitivity of two noninvasive blood pressure measurement techniques compared to telemetry in cynomolgus monkeys and beagle dogs.

Andrea Z Mitchell1, Carrie McMahon, Tom W Beck, R Dustan Sarazan.   

Abstract

INTRODUCTION: Animals are commonly used in toxicological research for the evaluation of drug effects on the cardiovascular system. Accurate and reproducible determination of blood pressure (BP) in conscious, manually restrained monkeys and dogs is a challenge with current non-invasive cuff techniques. The High Definition Oscillometry (HDO) technique enables real time measurements with immediate visual feedback via PC screen on data validity. HDO measurements are considerably faster with a duration of approximately 8 to 15s than conventional cuff methods that can take several minutes.
METHODS: HDO Memo Diagnostic Model Science and Cardell BP Monitor Model 9401 measurements were compared for accuracy and reliability with simultaneously recorded direct blood pressure data captured via radiotelemetry. Six monkeys and six dogs implanted with DSI PCT telemetry transmitters were used; BP data were collected by all methods under manual constraint and compared. Measurements were performed with HDO and Cardell in the presence of a BP lowering drug (hexamethonium bromide). Systolic, diastolic, mean arterial pressure, and pulse rate were determined before, during and following up to 10mg/kg hexamethonium administration via intravenous slow bolus injection.
RESULTS: Drug induced hemodynamic changes could be detected in monkeys and dogs with the HDO method but only in dogs with the Cardell method. Correlation coefficients were generally higher for HDO versus Telemetry than Cardell versus Telemetry comparisons, indicating that this novel, non-invasive technique produces reliable blood pressure data and is able to detect drug-induced hemodynamic changes. DISCUSSION: HDO provides an alternative approach for invasive telemetry surgeries to obtain reliable hemodynamic data in animal models for cardiovascular research when invasive techniques are not warranted. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20435151     DOI: 10.1016/j.vascn.2010.04.005

Source DB:  PubMed          Journal:  J Pharmacol Toxicol Methods        ISSN: 1056-8719            Impact factor:   1.950


  4 in total

1.  Comparison of Direct and Indirect Methods of Measuring Arterial Blood Pressure in Healthy Male Rhesus Macaques (Macaca mulatta).

Authors:  Logan K France; Meghan S Vermillion; Caroline M Garrett
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-01-01       Impact factor: 1.232

2.  Blood Pressure Reference Intervals for Ketamine-sedated Rhesus Macaques (Macaca mulatta).

Authors:  Rachel D Brownlee; Philip H Kass; Rebecca L Sammak
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-01-02       Impact factor: 1.232

3.  Interday variation and effect of transportation on indirect blood pressure measurements, plasma endothelin-1 and serum cortisol in Standardbred and Icelandic horses.

Authors:  Josefin Söder; Johan T Bröjer; Katarina Ea Nostell
Journal:  Acta Vet Scand       Date:  2012-06-10       Impact factor: 1.695

4.  Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment.

Authors:  Maria Lyberg; Ingrid Ljungvall; Jens Häggström; Ellinor Ahlund; Lena Pelander
Journal:  J Vet Intern Med       Date:  2021-02-15       Impact factor: 3.333

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.