Literature DB >> 20434900

Electronic tongue for simultaneous detection of endotoxins and other contaminants of microbiological origin.

Jorge Yánez Heras1, Diego Pallarola, Fernando Battaglini.   

Abstract

Endotoxins, also referred to as pyrogens, are lipopolysaccharides (LPS) present in the outer membrane of Gram-negative bacteria, and represent one of the most dangerous microbiological contaminants in water for hemodialysis and intravenous infusion. A method is presented for the simultaneous detection of endotoxins and other bacterial lysis contaminating species in purified water for parenteral formulations. The technique used is electrochemical impedance spectroscopy, with data interpretation using principal component analysis (PCA), cluster analysis (CA), and multivariate discriminant analysis (MDA). Two types of electrode surfaces were modified with LPS recognition agents: (i) a 37 amino acids fragment of a 18 kDa cationic antimicrobial protein (CAP18F) that has LPS binding activity; (ii) the highly selective endotoxin neutralizing protein (ENP). Statistical multivariate analysis of the impedance spectral data allowed the detection of endotoxin at, and below, the threshold pharmaceutical regulatory level. Discrimination of LPS from samples containing proteins, nucleic acids, phospholipids or their mixtures was achieved. These results open a new route to a practical instrumental method capable of detecting and discriminating LPS from other potential pro-inflammatory species of microbiological origin, such as nucleic acids. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20434900     DOI: 10.1016/j.bios.2010.04.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Biosensors for Detection of Human Placental Pathologies: A Review of Emerging Technologies and Current Trends.

Authors:  Jia Liu; Babak Mosavati; Andrew V Oleinikov; E Du
Journal:  Transl Res       Date:  2019-05-20       Impact factor: 7.012

2.  Preparation of a Peptide-Modified Electrode for Capture and Voltammetric Determination of Endotoxin.

Authors:  Tao Liu; Fanyu Meng; Wenbo Cheng; Haixuan Sun; Yan Luo; Yuguo Tang; Peng Miao
Journal:  ACS Omega       Date:  2017-06-05

3.  New bladder cancer non-invasive surveillance method based on voltammetric electronic tongue measurement of urine.

Authors:  Javier Monreal-Trigo; Miguel Alcañiz; M Carmen Martínez-Bisbal; Alba Loras; Lluís Pascual; José Luis Ruiz-Cerdá; Alberto Ferrer; Ramón Martínez-Máñez
Journal:  iScience       Date:  2022-08-04

4.  Novel SH-SAW Biosensors for Ultra-Fast Recognition of Growth Factors.

Authors:  Daniel Matatagui; Ágatha Bastida; M Carmen Horrillo
Journal:  Biosensors (Basel)       Date:  2021-12-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.