Transcutaneous aortic valve implantation using the axillary/subclavian access: feasibility and early clinical outcomes.

Thomas Modine1, Jean François Obadia, Emmanuel Choukroun, Gilles Rioufoul, Arnaud Sudre, Jean Claude Laborde, Pascal Leprince.   

Abstract

OBJECTIVE: Retrograde transfemoral artery catheterization is the most common way of implanting a percutaneous aortic valve. But in some cases, this access cannot be used and the subclavian artery access may represent an alternative to the femoral route, even offering certain advantages. This article describes prosthetic aortic valve implantation using the subclavian arterial approach and reports the findings.
METHODS: The valve prosthesis is a self-expandable, nitinol-based device (CoreValve; Medtronic Inc. Minneapolis, Minn). The axillary or subclavian artery was exposed with a small incision. Rapid ventricular pacing was used to reduce cardiac output while a routine aortic balloon valvuloplasty was performed. Then, an 18F sheath was inserted into the axillary artery down into the ascending aorta. By using this method, a prosthesis was implanted in 17 patients (aged 71±11 years) whose surgical risk was deemed excessive because of severe comorbidity and in whom transfemoral catheterization was considered unfeasible or at risk of severe complications.
RESULTS: Subclavian arterial injury did not occur in any patient. The postprocedural aortic valve area increased from 0.6±0.3 cm2 to 1.44±0.35 cm2. A transient ischemic attack occurred in 1 patient. Two patients experienced transitory brachial plexus deficit. There were no intraprocedural deaths. Two deaths occurred in the 30-day follow-up period.
CONCLUSIONS: This initial experience suggests that subclavian transarterial aortic valve implantation, in selected high-risk patients, is feasible and safe with satisfactory short-term outcomes. Copyright Â
© 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 20434180     DOI: 10.1016/j.jtcvs.2010.01.044

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Society of Thoracic Surgeons Risk Score predicts hospital charges and resource use after aortic valve replacement.

Authors:  George J Arnaoutakis; Timothy J George; Diane E Alejo; Christian A Merlo; William A Baumgartner; Duke E Cameron; Ashish S Shah
Journal:  J Thorac Cardiovasc Surg       Date:  2011-04-17       Impact factor: 5.209

2.  Retrograde, transsubclavian implantation of a SAPIEN XT™ aortic valve prosthesis with the Edwards NovaFlex+™ system.

Authors:  J Blumenstein; A Van Linden; J Kempfert; Woung-Keung Kim; C Liebetrau; C Hamm; H Nef; T Walther; H Moellmann
Journal:  Clin Res Cardiol       Date:  2012-05-03       Impact factor: 5.460

3.  Safety and efficacy of the subclavian access route for TAVI in cases of missing transfemoral access.

Authors:  Andrea Muensterer; Domenico Mazzitelli; Hendrik Ruge; Anke Wagner; Ina Hettich; Nicolo Piazza; Ruediger Lange; Sabine Bleiziffer
Journal:  Clin Res Cardiol       Date:  2013-05-11       Impact factor: 5.460

4.  Percu-Ax aortic valve implantation with a double arm approach: a case report.

Authors:  Carlo Trani; Cristina Aurigemma; Enrico Romagnoli; Francesco Burzotta
Journal:  Eur Heart J Case Rep       Date:  2020-10-16

5.  Patient selection for transcatheter aortic valve implantation: An interventional cardiology perspective.

Authors:  Darrren Mylotte; Giuseppe Martucci; Nicolo Piazza
Journal:  Ann Cardiothorac Surg       Date:  2012-07

6.  The next revolution: percutaneous aortic valve replacement.

Authors:  Martin B Leon; Eugenia Nikolsky
Journal:  Rambam Maimonides Med J       Date:  2010-10-31

7.  The Transaxillary Approach via Prosthetic Conduit for Transcatheter Aortic Valve Replacement With the New-Generation Balloon-Expandable Valves in Patients With Severe Peripheral Artery Disease.

Authors:  Alexander Lind; Alina Zubarevich; Arjang Ruhparwar; Matthias Totzeck; Rolf Alexander Jánosi; Tienush Rassaf; Fadi Al-Rashid
Journal:  Front Cardiovasc Med       Date:  2022-01-13

8.  CT Angiography Analysis of Axillary Artery Diameter versus Common Femoral Artery Diameter: Implications for Axillary Approach for Transcatheter Aortic Valve Replacement in Patients with Hostile Aortoiliac Segment and Advanced Lung Disease.

Authors:  Rajiv Tayal; Humayun Iftikhar; Benjamin LeSar; Rahul Patel; Naveen Tyagi; Marc Cohen; Najam Wasty
Journal:  Int J Vasc Med       Date:  2016-03-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.