Literature DB >> 20433969

Fabrication and performance evaluation of highly sensitive hybrid sol-gel-derived oxygen sensor films based on a fluorinated precursor.

Juncal Estella1, Dorota Wencel, John P Moore, Maja Sourdaine, Colette McDonagh.   

Abstract

This paper describes the fabrication and performance of a range of highly sensitive luminescence-based oxygen sensor films based on the fluorinated sol-gel precursor 3,3,3-trifluoropropyltrimethoxysilane (TFP-TMOS). The oxygen-sensitive ruthenium complex [Ruthenium(II)-tris(4,7-diphenyl-1,10-phenanthroline)] dichloride, [Ru(dpp)(3)](2+) was entrapped in a wide range of ORMOSILs (organically modified silicates) matrices composed of alkyl and TFP-TMOS sol-gel precursors in different relative ratios. The influence of TFP-TMOS on sensor sensitivity, humidity-sensitivity and long-term stability was investigated and performance was compared to that of similar but non-fluorinated films. The optimum limit of detection was found to be 0.002% of oxygen for the propyltriethoxysilane (PTEOS)/TFP-TMOS-derived film compared to 0.09% for PTEOS-derived films reported previously. Photobleaching of the luminescent complex in fluorinated and non-fluorinated matrices was also investigated. It was established that photobleaching was reduced but not eliminated in fluorinated films. All films produced in this study exhibit very good reproducibility, reversibility, enhanced sensitivity, humidity-insensitivity and long-term stability. 2010 Elsevier B.V. All rights reserved.

Entities:  

Year:  2010        PMID: 20433969     DOI: 10.1016/j.aca.2010.03.053

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles.

Authors:  Zike Jiang; Xinsheng Yu; Shikui Zhai; Yingyan Hao
Journal:  Sensors (Basel)       Date:  2017-03-09       Impact factor: 3.576

Review 2.  Oxygen Sensing, Hypoxia Tracing and in Vivo Imaging with Functional Metalloprobes for the Early Detection of Non-communicable Diseases.

Authors:  Vincenzo Mirabello; Fernando Cortezon-Tamarit; Sofia I Pascu
Journal:  Front Chem       Date:  2018-02-23       Impact factor: 5.221

Review 3.  Porous matrix materials in optical sensing of gaseous oxygen.

Authors:  I Dalfen; S M Borisov
Journal:  Anal Bioanal Chem       Date:  2022-03-29       Impact factor: 4.478

4.  Tuning the dynamic range and sensitivity of optical oxygen-sensors by employing differently substituted polystyrene-derivatives.

Authors:  Klaus Koren; Lukas Hutter; Barbara Enko; Andreas Pein; Sergey M Borisov; Ingo Klimant
Journal:  Sens Actuators B Chem       Date:  2013-01       Impact factor: 7.460

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.