Literature DB >> 20433298

Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost?: presented at the 2009 Joint Spine Section Meeting.

Leonardo B C Brasiliense1, Nicholas Theodore, Bruno C R Lazaro, Zafar A Sayed, Fatih Ersay Deniz, Volker K H Sonntag, Neil R Crawford.   

Abstract

OBJECT: The object of this study was to investigate the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of thoracic pedicle screws.
METHODS: Forty human thoracic vertebrae (T6-11) from human cadavers were studied. Before pedicle screws were inserted, the specimens were separated into 4 groups according to the type of screw used: 1) standard pedicle screw (no cortical perforation); 2) screw with medial cortical perforation; 3) screw with lateral cortical perforation; and 4) "airball" screw (a screw that completely missed the vertebral body). Consistency among the groups for bone mineral density, pedicle diameter, and screw insertion depth was evaluated. Finally, each screw was pulled out at a constant displacement rate of 10 mm/minute while ultimate strength was recorded.
RESULTS: Compared with well-placed pedicle screws, medially misplaced screws had 8% greater mean pullout strength (p = 0.482) and laterally misplaced screws had 21% less mean pullout strength (p = 0.059). The difference in mean pullout strength between screws with medial and lateral cortical perforations was significant (p = 0.013). Airball screws had only 66% of the mean pullout strength of well-placed screws (p = 0.009) and had 16% lower mean pullout strength than laterally misplaced screws (p = 0.395).
CONCLUSIONS: This in vitro study showed a significant difference in mean pullout strength between medial and lateral misplaced pedicle screws. Moreover, airball screws were associated with a significant loss of pullout strength.

Entities:  

Mesh:

Year:  2010        PMID: 20433298     DOI: 10.3171/2009.11.SPINE09408

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  12 in total

1.  Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

Authors:  Takahiro Makino; Takashi Kaito; Hiroyasu Fujiwara; Kazuo Yonenobu
Journal:  Eur Spine J       Date:  2012-02-19       Impact factor: 3.134

2.  Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study.

Authors:  Claudio Lamartina; Riccardo Cecchinato; Zsolt Fekete; Alberto Lipari; Meinrad Fiechter; P Berjano
Journal:  Eur Spine J       Date:  2015-10-23       Impact factor: 3.134

Review 3.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

4.  Usefulness of Preoperative Planning by Three-Dimensional Planning Software for Pedicle Screw Placement in Thoracolumbar Surgeries: Misplacement Rate and Associated Risk Factors.

Authors:  Tomonori Ozaki; Kentaro Yamada; Hiroaki Nakamura
Journal:  Spine Surg Relat Res       Date:  2021-11-04

5.  Size selection and placement of pedicle screws using robot-assisted versus fluoroscopy-guided techniques for thoracolumbar fractures: possible implications for the screw loosening rate.

Authors:  Sheng-Yang Du; Jun Dai; Jing-Yan Yang; Lei Cao; Xiao-Zhong Zhou; Zhen-Tao Zhou; Bing-Chen Shan; Feng-Xian Jiang
Journal:  BMC Surg       Date:  2022-10-22       Impact factor: 2.030

6.  Currently Adopted Criteria for Pedicle Screw Diameter Selection.

Authors:  Giovanni F Solitro; Keith Whitlock; Farid Amirouche; Ankit I Mehta; Annie McDonnell
Journal:  Int J Spine Surg       Date:  2019-04-30

7.  Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study.

Authors:  Shyam K Saraf; Ravindra P Singh; Vakil Singh; Ashish Varma
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

8.  Intraoperative computed tomography navigation for transpedicular screw fixation to treat unstable thoracic and lumbar spine fractures: clinical analysis of a case series (CARE-compliant).

Authors:  Ching-Yu Lee; Meng-Huang Wu; Yen-Yao Li; Chin-Chang Cheng; Chu-Hsiang Hsu; Tsung-Jen Huang; Robert Wen-Wei Hsu
Journal:  Medicine (Baltimore)       Date:  2015-05       Impact factor: 1.889

9.  The effect of lateral wall perforation on screw pull-out strength: a cadaveric study.

Authors:  Nan Li; Da He; Yonggang Xing; Yanwei Lv; Wei Tian
Journal:  J Orthop Surg Res       Date:  2015-01-24       Impact factor: 2.359

10.  Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws.

Authors:  Michael Siu Hei Tse; Chi Hin Chan; Kam Kwong Wong; Wing Cheung Wong
Journal:  Asian Spine J       Date:  2016-08-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.