Literature DB >> 20432347

Three-dimensional balanced steady state free precession imaging of the prostate: flip angle dependency of the signal based on a two component T2-decay model.

Tryggve H Storås1, Kjell-Inge Gjesdal, Oystein B Gadmar, Jonn-Terje Geitung, Nils-Einar Kløw.   

Abstract

PURPOSE: To investigate the contrast of three-dimensional balanced steady state free precession (3D bSSFP) in the two component T2 model and to apply the results to optimize 3D bSSFP for prostate imaging at 1.5 Tesla.
MATERIALS AND METHODS: In each of seven healthy volunteers, six 3D bSSFP acquisitions were performed with flip angles (alpha) equally spaced between 10 degrees and 110 degrees . Predictions of signal and contrast were obtained from synthetic bSSFP images calculated from relaxation parameters obtained from a multi-spin-echo acquisition. One biexponential and two monoexponential models were applied. Measured and predicted signals were compared by simple linear regression.
RESULTS: The measured contrast to signal ratio increased continuously with alpha. Mean R(2) for the biexponential model was almost constant for alpha in the range 50-110 degrees . The biexponential model was a better predictor of the measured signal than the monoexponential model. A monoexponential model restricted to the echoes TE = 50-125 ms performed similar to the biexponential model. The predicted contrast peaked at alpha between 50 degrees and 90 degrees .
CONCLUSION: Prostate imaging with bSSFP benefited from high flip angles. The biexponential model provided good signal prediction while predictions from the monoexponential models are dependent on the range of TE used for T2 determination. Copyright 2010 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 20432347     DOI: 10.1002/jmri.22135

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  MR measurement of luminal water in prostate gland: Quantitative correlation between MRI and histology.

Authors:  Shirin Sabouri; Ladan Fazli; Silvia D Chang; Richard Savdie; Edward C Jones; S Larry Goldenberg; Peter C Black; Piotr Kozlowski
Journal:  J Magn Reson Imaging       Date:  2017-01-27       Impact factor: 4.813

2.  Luminal Water Imaging: A New MR Imaging T2 Mapping Technique for Prostate Cancer Diagnosis.

Authors:  Shirin Sabouri; Silvia D Chang; Richard Savdie; Jing Zhang; Edward C Jones; S Larry Goldenberg; Peter C Black; Piotr Kozlowski
Journal:  Radiology       Date:  2017-04-10       Impact factor: 11.105

Review 3.  Limitations and Prospects for Diffusion-Weighted MRI of the Prostate.

Authors:  Roger Bourne; Eleftheria Panagiotaki
Journal:  Diagnostics (Basel)       Date:  2016-05-27
  3 in total