Literature DB >> 20432316

Concatenated and parallel optimization for the estimation of T1 map in FLASH MRI with multiple flip angles.

Defeng Wang1, Lin Shi, Yi-Xiang J Wang, Jing Yuan, David K W Yeung, Ann D King, Anil T Ahuja, Pheng Ann Heng.   

Abstract

Most traditional methods for T(1) map estimation in MRI with fast low-angle-shot sequences are aimed at high efficiency by compromising the fitting accuracy. In this paper, the fundamental problem of parameter estimation in fast low-angle-shot MRI was re-examined, and an accurate and fast optimization approach, named concatenated optimization for parameter estimation, was proposed for the regression of data points acquired with multiple flip angles. The initial estimation of T(1) was obtained from the linear regression, followed by the constrained nonlinear regression based on the initial estimates. This heterogeneous initialization strategy improves the fitting accuracy and reduces the computational time. A computationally efficient implementation of concatenated optimization for parameter estimation was achieved based on the graphic processing unit, named as concatenated optimization for parameter estimation graphic processing unit. In experimental comparison with Fram's method and the Fitter Tool in Jim, the proposed methods are capable of achieving significantly higher efficiency and more accurate estimations. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20432316     DOI: 10.1002/mrm.22294

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Estimating T1 from multichannel variable flip angle SPGR sequences.

Authors:  Joshua D Trzasko; Petrice M Mostardi; Stephen J Riederer; Armando Manduca
Journal:  Magn Reson Med       Date:  2012-07-17       Impact factor: 4.668

2.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

3.  Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck.

Authors:  Jing Yuan; Steven Kwok Keung Chow; David Ka Wai Yeung; Anil T Ahuja; Ann D King
Journal:  Quant Imaging Med Surg       Date:  2012-12

4.  Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

Authors:  Gunther Helms; Henning Dathe; Nikolaus Weiskopf; Peter Dechent
Journal:  Magn Reson Med       Date:  2011-03-22       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.