Literature DB >> 20430597

Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on a carbon ionic liquid electrode modified with mesoporous molecular sieve MCM-41.

Yonghong Li1, Xiandong Zeng, Xiaoying Liu, Xinsheng Liu, Wanzhi Wei, Shenglian Luo.   

Abstract

The direct electron transfer and electrocatalysis of hemoglobin (Hb) entrapped in the MCM-41 modified carbon ionic liquid electrode (CILE) were investigated by using cyclic voltammetry in 0.10 M pH 7.0 phosphate buffer solution (PBS). Due to its uniform pore structure, high surface areas and good biocompatibility, the mesoporous silica sieve MCM-41 provided a suitable matrix for immobilization of biomolecule. The MCM-41 modified CILE showed significant promotion to the direct electron transfer of Hb, which exhibited a pair of well defined and quasi-reversible peaks for heme Fe(III)/Fe(II) with a formal potential of -0.284 V (vs. Ag/AgCl). Additionally, the Hb immobilized on the MCM-41 modified carbon ionic liquid electrode showed excellent electrocatalytic activity toward H(2)O(2). The electrocatalytic current values were linear with increasing concentration of H(2)O(2) in a wide range of 5-310 microM and the corresponding detection limit was calculated to be 5 x 10(-8)M (S/N=3). The surface coverage of Hb immobilized on the MCM-41 modified carbon ionic liquid electrode was about 2.54 x 10(-9) molcm(-2). The Michaelis-Menten constant K(m)(app) of 214 microM indicated that the Hb immobilized on the modified electrode showed high affinity to H(2)O(2). The proposed electrode had high stability and good reproducibility due to the protection effect of MCM-41 and ionic liquid, and it would have wide potential applications in direct electrochemistry, biosensors and biocatalysis. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20430597     DOI: 10.1016/j.colsurfb.2010.04.001

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  2 in total

1.  Development of a new sensitive immunostrip assay based on mesoporous silica and colloidal Au nanoparticles.

Authors:  Kobra Omidfar; Behnosh Khorsand; Bagher Larijani
Journal:  Mol Biol Rep       Date:  2011-05-21       Impact factor: 2.316

2.  Rationally designed naphthyl substituted amine functionalized ionic liquid platform for covalent immobilization and direct electrochemistry of hemoglobin.

Authors:  K Theyagarajan; Duraisamy Saravanakumar; Sellappan Senthilkumar; Kathavarayan Thenmozhi
Journal:  Sci Rep       Date:  2019-07-18       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.