Abstract

Uniaxial and biaxial mechanical properties of purified elastic tissue from the proximal thoracic aorta were studied to understand physiological load distributions within the arterial wall. Stress-strain behaviour was non-linear in uniaxial and inflation tests. Elastic tissue was 40% stiffer in the circumferential direction compared to axial in uniaxial tests and approximately 100% stiffer in vessels at an axial stretch ratio of 1.2 or 1.3 and inflated to physiological pressure. Poisson's ratio v(thetaz) averaged 0.2 and v(ztheta) increased with circumferential stretch from approximately 0.2 to approximately 0.4. Axial stretch had little impact on circumferential behaviour. In intact (unpurified) vessels at constant length, axial forces decreased with pressure at low axial stretches but remained constant at higher stretches. Such a constant axial force is characteristic of incrementally isotropic arteries at their in vivo dimensions. In purified elastic tissue, force decreased with pressure at all axial strains, showing no trend towards isotropy. Analysis of the force-length-pressure data indicated a vessel with v(thetaz) approximately 0.2 would stretch axially 2-4% with the cardiac pulse yet maintain constant axial force. We compared the ability of 4 mathematical models to predict the pressure-circumferential stretch behaviour of tethered, purified elastic tissue. Models that assumed isotropy could not predict the stretch at zero pressure. The neo-Hookean model overestimated the non-linearity of the response and two non-linear models underestimated it. A model incorporating contributions from orthogonal fibres captured the non-linearity but not the zero-pressure response. Models incorporating anisotropy and non-linearity should better predict the mechanical behaviour of elastic tissue of the proximal thoracic aorta. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20430395     DOI: 10.1016/j.jbiomech.2010.04.014

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  14 in total

1.  Anisotropic residual stresses in arteries.

Authors:  Taisiya Sigaeva; Gerhard Sommer; Gerhard A Holzapfel; Elena S Di Martino
Journal:  J R Soc Interface       Date:  2019-02-28       Impact factor: 4.118

2.  Insights into regional adaptations in the growing pulmonary artery using a meso-scale structural model: effects of ascending aorta impingement.

Authors:  Bahar Fata; Will Zhang; Rouzbeh Amini; Michael S Sacks
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

3.  Transmural variation in elastin fiber orientation distribution in the arterial wall.

Authors:  Xunjie Yu; Yunjie Wang; Yanhang Zhang
Journal:  J Mech Behav Biomed Mater       Date:  2017-08-05

4.  New interpretation of arterial stiffening due to cigarette smoking using a structurally motivated constitutive model.

Authors:  M S Enevoldsen; K-A Henneberg; J A Jensen; L Lönn; J D Humphrey
Journal:  J Biomech       Date:  2011-02-18       Impact factor: 2.712

5.  Regional structural and biomechanical alterations of the ovine main pulmonary artery during postnatal growth.

Authors:  Bahar Fata; Christopher A Carruthers; Gregory Gibson; Simon C Watkins; Danielle Gottlieb; John E Mayer; Michael S Sacks
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

6.  Arterial mechanics considering the structural and mechanical contributions of ECM constituents.

Authors:  Yunjie Wang; Shahrokh Zeinali-Davarani; Yanhang Zhang
Journal:  J Biomech       Date:  2016-02-24       Impact factor: 2.712

7.  From Uniaxial Testing of Isolated Layers to a Tri-Layered Arterial Wall: A Novel Constitutive Modelling Framework.

Authors:  Alessandro Giudici; Ashraf W Khir; Jason M Szafron; Bart Spronck
Journal:  Ann Biomed Eng       Date:  2021-06-03       Impact factor: 3.934

8.  A structural constitutive model considering angular dispersion and waviness of collagen fibres of rabbit facial veins.

Authors:  Aristotelis Agianniotis; Rana Rezakhaniha; Nikos Stergiopulos
Journal:  Biomed Eng Online       Date:  2011-03-04       Impact factor: 2.819

Review 9.  Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries.

Authors:  Charanpreet Singh; Cynthia S Wong; Xungai Wang
Journal:  J Funct Biomater       Date:  2015-06-30

Review 10.  Arterial Stiffness.

Authors:  Alberto Avolio
Journal:  Pulse (Basel)       Date:  2013-03-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.