Study of Gafchromic EBT film response over a large dose range.

Mária Martisíková1, Oliver Jäkel.   

Abstract

Presently Gafchromic EBT films are widely used for relative dose verification in standard radiation therapy using high-energy photons, inclusive IMRT. The use of films for dosimetry in medical ion beams is more complicated due to the strongly inhomogeneous dose deposition by ions on microscopic level. Track structure models, presently used to describe dosimeter response as a function of the ion field properties, are based on input information which can be obtained from the film response in photon beams. We therefore studied the performance of Gafchromic EBT films, ancestors of currently available EBT2 films, in (60)Co photon beams. The dose-response curve was measured from 7.5 x 10(-2) Gy to 3 x 10(4) Gy. The dynamic range, linearity and dose rate dependence of this calibration curve were studied. A high saturation dose of 3 x 10(3) Gy, and thus a large dynamic range, was observed. No signs of supralinearity and bleaching due to radiation were found. No dependence of the response on the dose rate at high dose rates and high doses was found. All those properties justify the use of simplified models of the film response to ions. Furthermore, fits of the calibration data by predictions of different models for signal creation mechanism of dosimetric materials were performed. The best description was found for the recently published gamma-distributed single-hit model which takes into account different sizes of the active centres.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20427857     DOI: 10.1088/0031-9155/55/10/N03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Monte Carlo and ray tracing algorithms in the cyberknife treatment planning for lung tumours- comparison and validation.

Authors:  V Murali; P G Gopalakrishna Kurup; N Bhuvaneswari; H Sudahar; M Muthukumaran
Journal:  J Radiosurg SBRT       Date:  2013

2.  3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.

Authors:  Charles K Matrosic; Wesley Culberson; Andrew Shepard; Sydney Jupitz; Bryan Bednarz
Journal:  Phys Med       Date:  2021-04-23       Impact factor: 2.685

3.  Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.

Authors:  Andreas Franz Resch; Paul David Heyes; Hermann Fuchs; Niels Bassler; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2020-03-13       Impact factor: 4.071

4.  Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams.

Authors:  Andreas F Resch; Fatima Padilla Cabal; Milovan Regodic; Wolfgang Lechner; Gerd Heilemann; Peter Kuess; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2022-07-14       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.