Literature DB >> 20426630

Contemporary results of endovascular repair of abdominal aortic aneurysms: effect of anatomical fixation on outcomes.

Jeffrey P Carpenter1, Mark J Garcia, Stuart A Harlin, William D Jordan, Matthew T Jung, Zvonimir Krajcer, Julio A Rodriguez-Lopez.   

Abstract

PURPOSE: To report the contemporary controlled trial experience with the fully supported unibody Powerlink stent-graft for endovascular treatment of abdominal aortic aneurysm (AAA).
METHODS: Between 2000 and 2008, 3 prospective multicenter trials of the Powerlink system evaluated 157 AAA patients (141 men; mean age 72.0+/-9.1 years) with mean AAA sac diameter of 5.6+/-0.9 cm who received a bifurcated stent-graft featuring anatomical fixation at the aortoiliac bifurcation and proximal sealing with extension stent-grafts as needed. Challenging infrarenal aortic neck anatomy was present in 83% of patients. Postoperative follow-up occurred at defined intervals to 5 years.
RESULTS: Technical success was achieved in 99% of patients. Aneurysm exclusion was achieved in all patients over a mean procedure time of 132+/-58 minutes. No aneurysm-related deaths, ruptures, conversions, or migrations have been observed to current follow-up as these aneurysms have continued to remodel, with > or =92% of patients free from sac growth.
CONCLUSION: The implant technique of placing a fully-supported unibody stent-graft at the aortoiliac bifurcation with proximal sealing appears to safely and effectively reline the aorta and exclude aneurysms. Results from controlled clinical trial experience suggest this algorithm can provide stable, secure fixation for patients with challenging infrarenal aortic neck anatomy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20426630     DOI: 10.1583/09-2977.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  6 in total

1.  Use of the IntuiTrak stent-graft delivery system for percutaneous abdominal aortic aneurysm exclusion: initial single-center experience.

Authors:  Cindy W Tom; Zvonimir Krajcer
Journal:  Tex Heart Inst J       Date:  2010

2.  Endovascular repair of a common iliac pseudoaneurysm and aortic ectasia in a patient with horseshoe kidney and pancreatitis: a case report.

Authors:  Abdullah Fakhro; Nilay Shah; T L Barnes
Journal:  Ann Med Surg (Lond)       Date:  2013-11-04

3.  Initial Clinical Experience with the Endologix AFX Unibody Stent Graft System for Treating Patients with Abdominal Aortic Aneurysms: A Case Controlled Comparative Study.

Authors:  George N Kouvelos; Petroula Nana; Vasilios Bouris; Michalis Peroulis; Aikaterini Drakou; Nikolaos Rousas; Athanasios Giannoukas; Miltiadis I Matsagkas
Journal:  Vasc Specialist Int       Date:  2017-03-31

4.  Unibody Endograft Using AFX 2 for Less Invasive and Faster Endovascular Aortic Repair: Protocol for a Multicenter Nonrandomized Study.

Authors:  Roberto Silingardi; Pasqualino Sirignano; Francesco Andreoli; Wassim Mansour; Mattia Migliari; Francesco Speziale
Journal:  JMIR Res Protoc       Date:  2020-04-06

5.  Midterm outcomes of 455 patients receiving the AFX2 endovascular graft for the treatment of abdominal aortic aneurysm: A retrospective multi-center analysis.

Authors:  Raymond Vetsch; Harvey E Garrett; Christopher L Stout; Alan R Wladis; Matt Thompson; Joseph V Lombardi
Journal:  PLoS One       Date:  2021-12-31       Impact factor: 3.240

6.  Use of the AFX Stent Graft in Patients with Extremely Narrow Aortic Bifurcation: A Multicenter Retrospective Study.

Authors:  M U Wagenhäuser; N Floros; E Nikitina; J Mulorz; K M Balzer; S Goulas; M Petrich; P Dueppers; F Simon; H Schelzig; A Oberhuber
Journal:  Int J Vasc Med       Date:  2021-10-04
  6 in total