Literature DB >> 2042090

Evaluation of a new percutaneous stainless steel Greenfield filter by intravascular ultrasonography.

L J Greenfield1, J R Tauscher, M V Marx.   

Abstract

The standard stainless steel Greenfield filter was modified by extending the limbs at the apex to permit loading into a 12F carrier for percutaneous insertion. This model was tested for fixation and resolution of experimental embolism in dogs (six filters in four dogs) and sheep (eight suprarenal filters in eight sheep). Serial radiographs and venacavography at 2 and 4 weeks allowed measurement of migration and suspected caval penetration, confirmed by direct examination at autopsy. Caval penetration was graded according to visibility of point (0), hook (1+), or limb (2+) for each limb of the filter. Oxidized cellulose-induced thrombi were injected and trapped in two dogs and four sheep without proximal filter displacement or thrombus propagation. Thrombi showed incomplete resolution during 4 weeks' observation by interval venacavography and subsequent autopsy but no tendency for proximal propagation. Distal migration occurred in four of six filters in dogs, and caval wall penetration was seen (score 1.8/filter). Less migration was seen in sheep (2/8), but there was evidence of hook penetration in four animals (score 0.88/filter). Intravascular ultrasonography, 20 MHz, with a 6.5 F catheter assembly successfully visualized all 10 filters in which it was attempted and showed thrombi attached to the filter or caval wall, all of which were confirmed at explant. No thrombi were missed; however, intravascular ultrasonography was limited in assessment of caval wall penetration by lack of position control and reverberation artifact. Although it performs well as a filter, the elasticity of the percutaneous stainless steel greenfield filter allows distal migration and caval penetration comparable to the titanium Greenfield filter and will require further modification of hook design to improve performance.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2042090

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  1 in total

1.  An unopened titanium Greenfield IVC filter: intravascular ultrasound to reveal associated thrombus and aid in filter opening.

Authors:  T C Goertzen; T C McCowan; K L Garvin; R P Lieberman; R F LeVeen
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Jul-Aug       Impact factor: 2.740

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.