Literature DB >> 2041848

'Tru-Cut' needle biopsy of the liver: importance of the correct technique.

B Maharaj1, S Pillay.   

Abstract

In order to determine which technique would provide adequate tissue for histological examination when the 'Tru-Cut' needle is used for liver biopsy, the livers of cadavers were biopsied by a single operator, under direct vision, using a 'Tru-Cut' needle. The modified breast biopsy technique either preceded or followed one of two alternative methods, one of which was recommended by the manufacturer, in a random manner. Thereafter, the biopsies were repeated using the alternative sequence. The mean length of the liver biopsy specimens that were obtained using the modified breast biopsy technique was 16.3 mm (range: 8-20 mm). The corresponding figures for the manufacturerer's method were 7.7 mm (range: 2-14 mm) and for the third technique were 2.7 mm (range: 0.5-8 mm). Three of the 40 specimens (7.5%) obtained using the latter technique fragmented when placed in formalin; this did not occur in any of the 40 specimens taken using the modified breast biopsy technique. This investigation indicates that the modified breast biopsy technique should be used when 'Tru-Cut' needle biopsy of the liver is performed. This provides specimens which are adequate for histological diagnosis. In addition, the safety of liver biopsy, which is compromised by poor technique, is improved. The alternative methods, including that recommended by the manufacturer, must be avoided.

Entities:  

Mesh:

Year:  1991        PMID: 2041848      PMCID: PMC2398980          DOI: 10.1136/pgmj.67.784.170

Source DB:  PubMed          Journal:  Postgrad Med J        ISSN: 0032-5473            Impact factor:   2.401


  2 in total

Review 1.  Liver biopsy: techniques, clinical applications, and complications.

Authors:  J E Hegarty; R Williams
Journal:  Br Med J (Clin Res Ed)       Date:  1984-04-28

2.  Reproducibility of liver biopsy diagnosis in relation to the size of the specimen.

Authors:  B Hølund; H Poulsen; P Schlichting
Journal:  Scand J Gastroenterol       Date:  1980       Impact factor: 2.423

  2 in total
  3 in total

1.  Laparotomic Approach for Collecting Serial Hepatic Biopsies in Rats (Rattus norvegicus) and Mice (Mus musculus).

Authors:  Jennifer-Marie Garofalo; Sasha P Black; Lisa B Martin
Journal:  J Am Assoc Lab Anim Sci       Date:  2016       Impact factor: 1.232

2.  Comparison of Tru-Cut Biopsy and Incisional Biopsy in Achieving Prompt Diagnosis of Maxillofacial Pathology.

Authors:  Parimal Ranchhod Kansagara; H R Shiva Kumar; Kirthi Kumar Rai; K R Chatura; Hetal Ashokkumar Bera
Journal:  J Maxillofac Oral Surg       Date:  2021-04-10

3.  Complications associated with percutaneous needle biopsy of the liver when one, two or three specimens are taken.

Authors:  B Maharaj; I G Bhoora
Journal:  Postgrad Med J       Date:  1992-12       Impact factor: 2.401

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.