Literature DB >> 20416411

An in vitro evaluation of zirconia surface roughness caused by different scaling methods.

Paolo Vigolo1, Melissa Motterle.   

Abstract

STATEMENT OF PROBLEM: Plaque control is essential for the prevention of inflammatory periodontal disease. Ultrasonic scaling and hand scaling have been shown to be effective for the removal of plaque. However, routine periodontal prophylactic procedures may alter the surface profile of restorative materials.
PURPOSE: The purpose of this study was to assess in vitro the changes in roughness of zirconia surfaces treated by various scaling procedures.
MATERIAL AND METHODS: One hundred forty identical disks (10 mm in diameter, 2 mm thick) were made. The specimens were divided into 7 groups of 20 each; the surfaces of the specimens were exposed to different types of scaling methods simulating standard clinical conditions. In the control group (C), no scaling procedures were performed; in the other groups, a steel curette (SC), a plastic curette (PC), a titanium curette (TC), a piezoelectric ultrasonic scaler (PUS), an ultrasonic scaler (US), and a magnetostrictive ultrasonic scaler (MUS) were used. The surface texture was analyzed quantitatively and qualitatively with a profilometer and a scanning electron microscope (SEM). A 1-way ANOVA was performed to assess whether roughness profile (Ra) differed among groups, while pairwise comparisons between groups were evaluated by the Tukey HSD test (alpha=.05).
RESULTS: The 1-way ANOVA revealed significant differences among groups (P<.001); the Tukey HSD test demonstrated that all methods achieved different results. Analysis of zirconia surfaces treated by different ultrasonic scaling systems demonstrated some deeper scratches, whereas zirconia instrumented with various types of periodontal curettes exhibited smaller scratches. Scaling with a steel curette produced the least alteration of zirconia surfaces.
CONCLUSIONS: All instrument types evaluated altered the smoothness of zirconia surfaces. Follow-up in vivo studies are indicated to assess potential clinical problems associated with increased roughness at the margin of zirconia restorations following routine dental prophylaxis.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20416411     DOI: 10.1016/S0022-3913(10)60059-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Effect of repeated ultrasonic instrumentation on single-unit crowns: a laboratory study.

Authors:  Florin Eggmann; Fabio Schiavone; Julia Amato; Annika Vahle; Roland Weiger; Nicola U Zitzmann
Journal:  Clin Oral Investig       Date:  2021-11-24       Impact factor: 3.573

2.  Comparative Evaluation of Surface Roughness of Porcelain Fused to Metal and Stainless-Steel Crown Following Ultrasonic and Hand Scaling: A Comparative Study.

Authors:  Hiroj Bagde; Nikhat Fatima; Pragati Sharma; Anant Ragav Sharma; Gaurav Agrawal; Pooja Agrawal
Journal:  Cureus       Date:  2022-07-22

3.  Qualitative Evaluation of the Effects of Professional Oral Hygiene Instruments on Prosthetic Ceramic Surfaces.

Authors:  Francesco Grande; Edoardo Mochi Zamperoli; Mario Cesare Pozzan; Fabio Tesini; Santo Catapano
Journal:  Materials (Basel)       Date:  2021-12-21       Impact factor: 3.623

4.  Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study.

Authors:  Nathan Chiang Ping Tan; Catherine M Miller; Elsa Antunes; Dileep Sharma
Journal:  Clin Exp Dent Res       Date:  2021-10-02

5.  Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report.

Authors:  Ramtin Sadid-Zadeh; Perng-Ru Liu; Ruth Aponte-Wesson; Sandra J O'Neal
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.