Literature DB >> 20412264

The pocket echocardiograph: validation and feasibility.

Benjamin C Culp1, Jonathan D Mock, Christopher D Chiles, William C Culp.   

Abstract

BACKGROUND: A new, miniaturized ultrasound device, the pocket echocardiograph (PE), is highly portable and can be carried inside a lab-coat pocket. Studies of this device are limited and have not examined the use by novice echocardiographers. We hypothesize that a novice echocardiographer can use PE to produce interpretable cardiac images, and that both novice and expert echocardiographers can use PE to accurately quantify ejection fraction.
METHODS: Unselected subjects (n = 40) in an echocardiography laboratory underwent blinded formal transthoracic echocardiography (TTE) and PE (Acuson P10, Siemens, Mountain View, CA, USA). A cardiology fellow with 2 months of echocardiography training acquired PE images. The fellow and an experienced echocardiographer interpreted the PE studies offline in a blinded fashion. To assess adequacy, studies were graded as technically adequate, limited, or inadequate. A visual estimation of ejection fraction was made. Comparisons were made to the formal reported TTE.
RESULTS: Subjects were heterogeneous, 43% male; age 64 ± 17 years, and ejection fraction 52.4%± 12.3%. All PE studies were interpretable, and the vast majority of PE and TTE images were considered technically adequate (77.5% and 85% respectively; P = 0.32). Ejection fraction showed a good correlation, bias, and limits of agreement for the fellow's interpretation (r = 0.78, -5.9%, ±16.6%) with stronger association for the experienced echocardiographer (r = 0.88, -0.8%, ±11.4%).
CONCLUSION: Novice echocardiographers using the PE can produce adequate quality images. Both expert and novice echocardiographers can use PE to quantify ejection fraction over a broad range of patients. The device's low cost and portability may greatly expand the availability of bedside echocardiography for routine or urgent cardiovascular assessment.
© 2010, The Authors Journal compilation © 2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20412264     DOI: 10.1111/j.1540-8175.2009.01125.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  12 in total

1.  Diagnostic capability of comprehensive handheld vs transthoracic echocardiography.

Authors:  Michael W Cullen; Lori A Blauwet; Ori M Vatury; Sharon L Mulvagh; Thomas R Behrenbeck; Christopher G Scott; Patricia A Pellikka
Journal:  Mayo Clin Proc       Date:  2014-03-29       Impact factor: 7.616

2.  Smartphone interfaced handheld echocardiography for focused assessment of ventricular function and structure in children: A pilot study.

Authors:  Benjamin Acheampong; David A Parra; Muktar H Aliyu; Troy D Moon; Jonathan H Soslow
Journal:  Echocardiography       Date:  2019-12-27       Impact factor: 1.724

Review 3.  Focused cardiac ultrasound: where do we stand?

Authors:  Kirk T Spencer
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

4.  Handheld echocardiography during hospitalization for acute myocardial infarction.

Authors:  Michael W Cullen; Jeffrey B Geske; Nandan S Anavekar; J Wells Askew; Bradley R Lewis; Jae K Oh
Journal:  Clin Cardiol       Date:  2017-07-19       Impact factor: 2.882

5.  Feasibility and clinical utility of real-time tele-echocardiography using personal mobile device-based pocket echocardiograph.

Authors:  Paulina Wejner-Mik; Aleksandra Teneta; Mateusz Jankowski; Ludmiła Czyszpak; Katarzyna Wdowiak-Okrojek; Ewa Szymczyk; Jarosław D Kasprzak; Piotr Lipiec
Journal:  Arch Med Sci       Date:  2019-03-12       Impact factor: 3.707

6.  Utility of hand-held echocardiography in outpatient pediatric cardiology management.

Authors:  Alan Riley; Craig Sable; Aparna Prasad; Christopher Spurney; Ashraf Harahsheh; Sarah Clauss; Jessica Colyer; Marcin Gierdalski; Ashley Johnson; Gail D Pearson; Joanna Rosenthal
Journal:  Pediatr Cardiol       Date:  2014-06-10       Impact factor: 1.655

7.  Feasibility and reliability of point-of-care pocket-sized echocardiography.

Authors:  Garrett Newton Andersen; Bjørn Olav Haugen; Torbjørn Graven; Oyvind Salvesen; Ole Christian Mjølstad; Håvard Dalen
Journal:  Eur J Echocardiogr       Date:  2011-08-02

8.  Early markers of right heart involvement in regular smokers by Pocket Size Imaging Device.

Authors:  Vincenzo Schiano-Lomoriello; Roberta Esposito; Ciro Santoro; Giovanni de Simone; Maurizio Galderisi
Journal:  Cardiovasc Ultrasound       Date:  2015-07-23       Impact factor: 2.062

9.  The utility of pocket-sized echocardiography to assess left ventricular systolic function prior to permanent pacemaker implantation.

Authors:  Lawrence Lau; Robin Ducas; Jacques Rizkallah; Davinder S Jassal; Colette M Seifer
Journal:  Cardiovasc Ultrasound       Date:  2015-03-14       Impact factor: 2.062

Review 10.  Pocket-Sized Echocardiography Devices: One Stop Shop Service?

Authors:  Andreas Seraphim; Stavroula A Paschou; Julia Grapsa; Petros Nihoyannopoulos
Journal:  J Cardiovasc Ultrasound       Date:  2016-03-24
View more