Literature DB >> 20411100

False positive aortic dissection on abdominal ultrasound.

Clark Rosenberry1, Vincent Ball.   

Abstract

Entities:  

Year:  2010        PMID: 20411100      PMCID: PMC2850842     

Source DB:  PubMed          Journal:  West J Emerg Med        ISSN: 1936-900X


× No keyword cloud information.
A 43-year-old man presented to the emergency department (ED) with epigastric pain radiating down the center of his abdomen. He denied significant use of alcohol or non-steroidal anti-inflammatory drugs. He had uncontrolled hypertension on hydrochlorothiazide and a blood pressure of 185/95 mmHg. A two-dimensional aortic ultrasound was done at the patient’s bedside and revealed a double lumen and an intimal flap on the longitudinal axis (Figure 1). The transverse view was limited due to body habitus and bowel gas.
Figure 1.

Longitudinal ultrasound of abdominal aorta

Subsequent aortic computed tomography (CT) revealed an inflamed pancreatic head and a normal aorta (Figure 2). Lipase was elevated (1063 units/L). This patient’s aorta appeared as a false positive abdominal aortic dissection on bedside ED ultrasound. Radiologists refer to this aorta as normal despite its curvature. There is a case report of a tortuous thoracic aorta that led to a false positive descending thoracic aortic dissection on transesophageal echocardiogram.1 Severe tortuosity is usually seen in the thorax and may be associated with aortic aneurysms; however, this patient’s curvature does not indicate pathology. The abnormal curvature in this patient’s distal aorta allows for the impression on ultrasound that there is a false lumen and aneurysmal dilation. The retroaortic tissue appears to be a false lumen.
Figure 2.

Computed tomography aorta sagittal reconstruction. Arrow indicates location of transducer in Figure 1.

There is also the appearance of an intimal flap and communication with the false lumen on ultrasound. These findings are likely due to artifact created by overlying bowel gas, which is present directly above that segment of the aorta as seen on CT scan. Other explanations for the flap are less likely. First, the bifurcation of the aorta into the iliac arteries is farther caudal. Second, the inferior vena cava lies well to the right of this aorta and would not be seen as dorsal with our midline abdominal probe orientation. Third, there is only minimal curvature of the aorta in the coronal plane. Lastly, the only tissues directly surrounding this segment of the aorta are lymph nodes. False positive abdominal aortic dissections due to artifact associated with color Doppler ultrasound have been described,2,3 and false positives can occur with two-dimensional ultrasound.4,5 Our case is novel in that no reported instances of false positive abdominal aortic dissection on two-dimensional ultrasound are associated with an abnormal curvature of the aorta. This case emphasizes the importance of having multiple views on ultrasound to properly delineate anatomy. The transverse images of this patient’s aorta did not clearly reveal the vessel lumen, making our scan a limited one. The patient was ultimately admitted for pancreatitis, and the curvature in his aorta was an incidental finding.
  5 in total

1.  Tortuosity of the descending thoracic aorta simulating dissection on transesophageal echocardiography.

Authors:  E S Katz; R M Applebaum; J P Earls; G Krinsky; J Weinreb; I Kronzon
Journal:  J Am Soc Echocardiogr       Date:  1997 Jan-Feb       Impact factor: 5.251

2.  [Echocardiographic diagnosis of aortic dissection. Limits, pitfalls and difficulties].

Authors:  R Roudaut; M A Billes; P Gosse; T Laporte; M Dallocchio
Journal:  Arch Mal Coeur Vaiss       Date:  1987-11

3.  Pseudodissection of the abdominal aorta on color Doppler imaging.

Authors:  J M Crotty; M J Timken
Journal:  J Ultrasound Med       Date:  1995-11       Impact factor: 2.153

4.  False positive dissection of abdominal aortic aneurysm by color Doppler duplex ultrasonography.

Authors:  D Nguyen; U M Hamper
Journal:  J Ultrasound Med       Date:  1995-06       Impact factor: 2.153

5.  Two dimensional echocardiographic diagnosis of aortic dissection.

Authors:  M F Victor; G S Mintz; M N Kotler; A R Wilson; B L Segal
Journal:  Am J Cardiol       Date:  1981-12       Impact factor: 2.778

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.