Literature DB >> 20408122

Detection of hepatic metastases from colorectal cancer: prospective evaluation of gray scale US versus SonoVue® low mechanical index real time-enhanced US as compared with multidetector-CT or Gd-BOPTA-MRI.

V Cantisani1, P Ricci, M Erturk, E Pagliara, F Drudi, F Calliada, K Mortele, U D'Ambrosio, C Marigliano, C Catalano, D Marin, M Di Seri, F Longo, R Passariello.   

Abstract

PURPOSE: To compare ultrasound (US), low-mechanical index contrast enhanced US (CEUS) and multidetector-CT (MDCT) for the detection of hepatic metastases from colorectal cancer. METHODS AND MATERIALS: From January to June 2006, 110 patients (65 males, 45 females; mean age 62 years; range 39-78) with suspected hepatic lesions from colorectal cancer were prospectively evaluated with US, CEUS and MDCT by two independent readers. Intraoperative ultrasonography (IOUS, n = 45) or a follow-up up for at least 6 months by using MDCT or Gd-BOPTA-enhanced MRI was considered the gold standard. McNemar test was employed.
RESULTS: Reference standards revealed 430 metastases in 110 patients. On a patient-by-patients analysis, CEUS improved US sensitivity from 67.4-71.6% to 93.4-95.8% (p < 0.05). On a lesion-by-lesion analysis, CEUS improved the sensitivity of US from 60.9-64.9% to 85.3-92.8% (p < 0.001). The specificity increased from 50-60% to 76.7-83.3%. No significant differences in sensitivity or specificity between CEUS and MDCT were found. Contrast-enhanced US was significantly more sensitive than baseline US in the detection of metastases smaller than 1 cm (p < 0.001) with an increase in sensitivity from 29.1-35% to 63.3-76.6% no significant statistical difference was identified when compared with MDCT (sensitivity of 73.3-75.8%).
CONCLUSIONS: CEUS is significantly more accurate than US and highly comparable with MDCT in the detection of liver metastases from colorectal cancer. Therefore, in the evaluation of patients with suspected hepatic metastases from colorectal tumour, US examination must be performed after contrast administration. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20408122     DOI: 10.1055/s-0028-1109751

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  19 in total

Review 1.  Evolving clinical applications of contrast-enhanced ultrasound (CEUS) in the abdominal aorta.

Authors:  Vasileios Rafailidis; Sasan Partovi; Alexander Dikkes; Dean A Nakamoto; Nami Azar; Daniel Staub
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

2.  Multiparametric ultrasound evaluation with CEUS and shear wave elastography for carotid plaque risk stratification.

Authors:  N Di Leo; L Venturini; V de Soccio; V Forte; P Lucchetti; G Cerone; G Alagna; M Caratozzolo; D Messineo; C Di Gioia; L Di Marzo; D Fresilli; C De Vito; G Pugliese; V Cantisani; F D'Ambrosio
Journal:  J Ultrasound       Date:  2018-10-31

3.  Diagnostic imaging and CEUS findings in a rare case of Desmoid-type fibromatosis. A case report.

Authors:  Massimo Valentino; Mauro Liberatore; Fabrizio Maghella; Valeria De Soccio; Carlo De Felice; Daniela Messineo; Francesco Maria Drudi
Journal:  J Ultrasound       Date:  2018-03-21

4.  Isolated fallopian tube metastasis from colorectal cancer: ultrasonographic features.

Authors:  V Balaya; U Metzger; C Denet; M Herry; F Lecuru
Journal:  J Ultrasound       Date:  2017-08-21

Review 5.  Transcranial Doppler ultrasound in neurocritical care.

Authors:  Pablo Blanco; Anselmo Abdo-Cuza
Journal:  J Ultrasound       Date:  2018-02-10

6.  Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool.

Authors:  Mattia Di Segni; Valeria de Soccio; Vito Cantisani; Giacomo Bonito; Antonello Rubini; Gabriele Di Segni; Sveva Lamorte; Valentina Magri; Corrado De Vito; Giuseppe Migliara; Tommaso Vincenzo Bartolotta; Alessio Metere; Laura Giacomelli; Carlo de Felice; Ferdinando D'Ambrosio
Journal:  J Ultrasound       Date:  2018-04-21

Review 7.  Liver metastases: Contrast-enhanced ultrasound compared with computed tomography and magnetic resonance.

Authors:  Vito Cantisani; Hektor Grazhdani; Cristina Fioravanti; Maria Rosignuolo; Fabrizio Calliada; Daniela Messineo; Maria Giulia Bernieri; Adriano Redler; Carlo Catalano; Ferdinando D'Ambrosio
Journal:  World J Gastroenterol       Date:  2014-08-07       Impact factor: 5.742

8.  CEUS and strain elastography in gastric carcinoma.

Authors:  Vito Cantisani; Antonello Rubini; Guglielmo Miniagio
Journal:  J Ultrasound       Date:  2013-07-18

Review 9.  Non-invasive diagnostic imaging of colorectal liver metastases.

Authors:  Pier Paolo Mainenti; Federica Romano; Laura Pizzuti; Sabrina Segreto; Giovanni Storto; Lorenzo Mannelli; Massimo Imbriaco; Luigi Camera; Simone Maurea
Journal:  World J Radiol       Date:  2015-07-28

10.  CEUS in the differential diagnosis between biliary sludge, benign lesions and malignant lesions.

Authors:  Carla Serra; Cristina Felicani; Elena Mazzotta; Veronica Gabusi; Valentina Grasso; Antonio De Cinque; Lydia Giannitrapani; Maurizio Soresi
Journal:  J Ultrasound       Date:  2018-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.