Literature DB >> 20407905

Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study.

Won Ho Kim1, Byoung Kwon Lee, Sahng Lee, Jae-Min Shim, Jung-Sun Kim, Byoung-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong.   

Abstract

Morphologic changes of small-sized post-stent malapposition have not been sufficiently evaluated. We investigated serial changes of minimal post-stent malapposition with a follow-up optical coherence tomography (OCT) study. Post-stent OCT and intravascular ultrasound (IVUS) and follow-up OCT were performed in 26 patients with minimal post-stent malapposition. Serial changes of number and percent of malapposition struts, and mean extra-stent malapposition area were measured in OCT analysis. Zotarolimus-eluting stent (ZES), sirolimus-eluting stent (SES), and paclitaxel-eluting stent (PES) were deployed in 17, 7 and 2 patients, respectively. Mean durations of the follow-up OCT study were 5.7 ± 3.0 months. The minimal post-stent malapposition cannot be detected by the IVUS, but be visualized with an OCT examination. According to different drug-eluting stents, malapposed stent struts were defined as the struts with detachment from the vessel wall ≥160 μm for SES, ≥130 μm for PES, and ≥110 μm for ZES. The percent of malapposition struts significantly decreased from 12.2 ± 11.0% post-stent to 1.0 ± 2.2% follow-up (P < 0.001). There was a significant decrease in the mean extra-stent malapposition area from 0.35 ± 0.16 mm(2) post-stent to 0.04 ± 0.11 mm(2) follow-up (P < 0.001). Complete disappearance of stent malapposition was also observed in 22 (85%) patients. In conclusion, minimal stent malapposition which is not detectable by IVUS may disappear or decrease in follow-up OCT evaluation.

Entities:  

Mesh:

Year:  2010        PMID: 20407905     DOI: 10.1007/s00392-010-0163-5

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  22 in total

1.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.

Authors:  Ik-Kyung Jang; Brett E Bouma; Dong-Heon Kang; Seung-Jung Park; Seong-Wook Park; Ki-Bae Seung; Kyu-Bo Choi; Milen Shishkov; Kelly Schlendorf; Eugene Pomerantsev; Stuart L Houser; H Thomas Aretz; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2002-02-20       Impact factor: 24.094

2.  Background incidence of late malapposition after bare-metal stent implantation.

Authors:  Vivek M Shah; Gary S Mintz; Sue Apple; Neil J Weissman
Journal:  Circulation       Date:  2002-10-01       Impact factor: 29.690

3.  Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation.

Authors:  Myeong-Ki Hong; Gary S Mintz; Cheol Whan Lee; Young-Hak Kim; Seung-Whan Lee; Jong-Min Song; Ki-Hoon Han; Duk-Hyun Kang; Jae-Kwan Song; Jae-Joong Kim; Seong-Wook Park; Seung-Jung Park
Journal:  Circulation       Date:  2004-02-16       Impact factor: 29.690

4.  Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up.

Authors:  Myeong-Ki Hong; Gary S Mintz; Cheol Whan Lee; Duk-Woo Park; Kyoung-Min Park; Bong-Ki Lee; Young-Hak Kim; Jong-Min Song; Ki-Hoon Han; Duk-Hyun Kang; Sang-Sig Cheong; Jae-Kwan Song; Jae-Joong Kim; Seong-Wook Park; Seung-Jung Park
Journal:  Circulation       Date:  2006-01-24       Impact factor: 29.690

5.  Visualization of neointima formation by optical coherence tomography.

Authors:  Teruyoshi Kume; Takashi Akasaka; Takahiro Kawamoto; Nozomi Watanabe; Eiji Toyota; Renan Sukmawan; Yoshito Sadahira; Kiyoshi Yoshida
Journal:  Int Heart J       Date:  2005-11       Impact factor: 1.862

Review 6.  Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis.

Authors:  Ayman K M Hassan; Sandrin C Bergheanu; Theo Stijnen; Bas L van der Hoeven; Jaapjan D Snoep; Josepha W M Plevier; Martin J Schalij; J Wouter Jukema
Journal:  Eur Heart J       Date:  2009-01-21       Impact factor: 29.983

7.  Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition.

Authors:  Jun Tanigawa; Peter Barlis; Carlo Di Mario
Journal:  EuroIntervention       Date:  2007-05       Impact factor: 6.534

8.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

9.  Dose volume histogram assessment of late stent malapposition after intravascular brachytherapy.

Authors:  Christian E Dilcher; Rosanna C Chan; Jerzy Pregowski; Lukasz Kalinczuk; Gary S Mintz; Jun-ichi Kotani; Mariusz Kruk; Vivek M Shah; Daniel A Canos; Neil J Weissman; Ron Waksman
Journal:  Cardiovasc Radiat Med       Date:  2002 Jul-Dec

Review 10.  Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting.

Authors:  Giulio Guagliumi; Vasile Sirbu
Journal:  Catheter Cardiovasc Interv       Date:  2008-08-01       Impact factor: 2.692

View more
  9 in total

1.  Severe left main coronary stenosis in a young female patient, 6 years after mediastinal radiation therapy for non-Hodgkin lymphoma: assessment by coronary angiography and intravascular ultrasound.

Authors:  Grigorios Korosoglou; Arnt V Kristen; Martin Andrassy; Hugo A Katus; Stefan E Hardt
Journal:  Clin Res Cardiol       Date:  2012-04       Impact factor: 5.460

2.  Treatment of a large thrombus containing lesion with the MGuard protective net coronary stent system: optical coherence tomographic evidence of complete plaque sealing.

Authors:  Alessio La Manna; Salvatore Davide Tomasello; Corrado Tamburino
Journal:  Clin Res Cardiol       Date:  2010-06-30       Impact factor: 5.460

3.  Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Jung-Sun Kim; Changmyung Oh; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-31       Impact factor: 2.357

4.  [Progress in diagnostics is the driving force for developing interventional methods].

Authors:  R Erbel
Journal:  Herz       Date:  2011-08       Impact factor: 1.443

5.  Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.

Authors:  Yohei Uchimura; Tomonori Itoh; Hideto Oda; Yuya Taguchi; Wataru Sasaki; Kyosuke Kaneko; Tsubasa Sakamoto; Iwao Goto; Masafumi Sakuma; Masaru Ishida; Tatsuo Kikuchi; Daisuke Terashita; Hiromasa Otake; Yoshihiro Morino; Toshiro Shinke
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-29       Impact factor: 2.357

6.  Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry.

Authors:  Giuseppe Biondi-Zoccai; Imad Sheiban; Enrico Romagnoli; Stefano De Servi; Corrado Tamburino; Antonio Colombo; Francesco Burzotta; Patrizia Presbitero; Leonardo Bolognese; Leonardo Paloscia; Paolo Rubino; Gennaro Sardella; Carlo Briguori; Luigi Niccoli; Gianfranco Franco; Domenico Di Girolamo; Luigi Piatti; Cesare Greco; Davide Capodanno; Giuseppe Sangiorgi
Journal:  Clin Res Cardiol       Date:  2011-06-24       Impact factor: 5.460

7.  Long-Term Clinical Outcomes of Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation.

Authors:  Eui Im; Sung-Jin Hong; Chul-Min Ahn; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  J Am Heart Assoc       Date:  2019-04-02       Impact factor: 5.501

8.  Diagnostic imaging capabilities of the Ocelot -Optical Coherence Tomography System, ex-vivo evaluation and clinical relevance.

Authors:  Suhail Dohad; John Shao; Ian Cawich; Manish Kankaria; Arjun Desai
Journal:  BMC Med Imaging       Date:  2015-11-18       Impact factor: 1.930

Review 9.  Stent evaluation with optical coherence tomography.

Authors:  Seung-Yul Lee; Myeong-Ki Hong
Journal:  Yonsei Med J       Date:  2013-09       Impact factor: 2.759

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.