Literature DB >> 20403141

Solid phase HLA antibody detection technology--challenges in interpretation.

B D Tait1, F Hudson, G Brewin, L Cantwell, R Holdsworth.   

Abstract

The introduction into routine diagnostic laboratories of solid phase assays for human leukocyte antigen (HLA) antibody detection has resulted in the application of new laboratory matching algorithms in clinical organ transplantation which have improved pre-transplant detection of immunization, in turn resulting in avoidance of rejection in many cases which until their introduction would not have been possible using the historical complement dependent serological techniques. There have been two generations of solid phase assays introduced into routine practice, namely, the enzyme-linked immunosorbent assay (ELISA) technique and the use of fluorescent beads with HLA molecules bound to their surface which can either be used in conventional flow cytometry or in conjunction with Luminex instrumentation, the latter having become the most popular approach. The use of the fluorescent bead techniques has raised interesting questions both with respect to technical performance and the interpretation of the results obtained. The advantages of bead technology for HLA antibody determination and the technical issues requiring resolution are the subject of this review.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20403141     DOI: 10.1111/j.1399-0039.2010.01486.x

Source DB:  PubMed          Journal:  Tissue Antigens        ISSN: 0001-2815


  8 in total

1.  Microfluidic one-step synthesis of alginate microspheres immobilized with antibodies.

Authors:  Wanyu Chen; Jong-Hoon Kim; Di Zhang; Kyong-Hoon Lee; G A Cangelosi; S D Soelberg; C E Furlong; Jae-Hyun Chung; Amy Q Shen
Journal:  J R Soc Interface       Date:  2013-08-21       Impact factor: 4.118

2.  Donor-specific antibodies after ceasing immunosuppressive therapy, with or without an allograft nephrectomy.

Authors:  Arnaud Del Bello; Nicolas Congy-Jolivet; Federico Sallusto; Celine Guilbeau-Frugier; Isabelle Cardeau-Desangles; Marylise Fort; Laure Esposito; Joelle Guitard; Olivier Cointault; Laurence Lavayssière; Marie Béatrice Nogier; Antoine Blancher; Lionel Rostaing; Nassim Kamar
Journal:  Clin J Am Soc Nephrol       Date:  2012-05-24       Impact factor: 8.237

3.  Pretransplantation monitoring of HLA antibodies by complement dependent cytotoxicity and Luminex-based assays.

Authors:  Nataša Katalinić; Marina Fućak; Tajana Crnić; Milena Ćurković; Alma Starčević; Sanja Balen
Journal:  Wien Klin Wochenschr       Date:  2016-10-14       Impact factor: 1.704

Review 4.  Utility of HLA Antibody Testing in Kidney Transplantation.

Authors:  Ana Konvalinka; Kathryn Tinckam
Journal:  J Am Soc Nephrol       Date:  2015-03-24       Impact factor: 10.121

Review 5.  Interpreting Anti-HLA Antibody Testing Data: A Practical Guide for Physicians.

Authors:  Carrie A Schinstock; Manish J Gandhi; Mark D Stegall
Journal:  Transplantation       Date:  2016-08       Impact factor: 4.939

6.  Interlaboratory Comparison of the Results of Lifecodes LSA Class I and Class II Single Antigen Kits for Human Leukocyte Antigen Antibody Detection.

Authors:  Eun-Jee Oh; Hyewon Park; Kyoung Un Park; Eun-Suk Kang; Hyon-Suk Kim; Eun Young Song
Journal:  Ann Lab Med       Date:  2015-04-01       Impact factor: 3.464

7.  Improvement in the definition of anti-HLA antibody profile in highly sensitized patients.

Authors:  Juan Irure; Esther Asensio; Emilio Rodrigo; Íñigo Romón; Javier Gómez; Manuel Arias; Marcos López-Hoyos; David San Segundo
Journal:  PLoS One       Date:  2017-02-03       Impact factor: 3.240

8.  Many de novo donor-specific antibodies recognize β2 -microglobulin-free, but not intact HLA heterodimers.

Authors:  K Michel; R Santella; J Steers; A Sahajpal; F X Downey; V Thohan; M Oaks
Journal:  HLA       Date:  2016-04-06       Impact factor: 4.513

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.