Literature DB >> 20395651

A piezo-film-based measurement system for global haemodynamic assessment.

Fabrizio Clemente1, Pasquale Arpaia, Pasquale Cimmino.   

Abstract

A non-invasive piezo-film-based measurement method for haemodynamic assessment is proposed. The design of a system, able to reconstruct the blood pressure waveform online by dealing with problems arising from the piezo-film capacitive nature in the targeted frequency range (from quasi-dc up to 12 Hz), is illustrated. The system is based on a commercial piezo-film placed easily on the radial artery with a special brace without any discomfort for the patient. The analogical conditioning circuit and digital signal processing are continuously tuned with the signal from the sensor to reconstruct the blood pressure signal online. Diagnostic schema, based on physio-pathological models, have been implemented in order to compute online trends of max[dP(t)/d(t)] and volemic status highly useful for the intensivist and anaesthesiologist. The system was characterized by numerical simulation and experimental in vivo comparison to the traditional reference system.

Entities:  

Mesh:

Year:  2010        PMID: 20395651     DOI: 10.1088/0967-3334/31/5/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

2.  P(VDF-TrFE) polymer-based thin films deposited on stainless steel substrates treated using water dissociation for flexible tactile sensor development.

Authors:  Hong-Jie Tseng; Wei-Cheng Tian; Wen-Jong Wu
Journal:  Sensors (Basel)       Date:  2013-10-30       Impact factor: 3.576

3.  Machine learning techniques for arterial pressure waveform analysis.

Authors:  Vânia G Almeida; João Vieira; Pedro Santos; Tânia Pereira; H Catarina Pereira; Carlos Correia; Mariano Pego; João Cardoso
Journal:  J Pers Med       Date:  2013-05-02

4.  A Noncontact Method for Locating Radial Artery above Radial Styloid Process in Thermal Image.

Authors:  Xingguang Geng; Su Liu; Yitao Zhang; Jiena Hou; Shaolong Zhang; Jun Zhang; Haiying Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2020-05-07       Impact factor: 2.629

5.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

6.  Flexible PZT thin film tactile sensor for biomedical monitoring.

Authors:  Hong-Jie Tseng; Wei-Cheng Tian; Wen-Jong Wu
Journal:  Sensors (Basel)       Date:  2013-04-25       Impact factor: 3.576

7.  A 3D Wrist Pulse Signal Acquisition System for Width Information of Pulse Wave.

Authors:  Chuanglu Chen; Zhiqiang Li; Yitao Zhang; Shaolong Zhang; Jiena Hou; Haiying Zhang
Journal:  Sensors (Basel)       Date:  2019-12-18       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.