Literature DB >> 20394932

Computed tomography analysis of radiostereometric data to determine flexion axes after total joint replacement: application to the elbow joint.

A Ericson1, H Olivecrona, A Stark, M E Noz, G Q Maguire, M P Zeleznik, A Arndt.   

Abstract

Kinematic analysis for in vivo assessment of elbow endoprostheses requires knowledge of the exact positions of motion axes relative to bony landmarks or the prosthesis. A prosthesis-based reference system is required for comparison between individuals and studies. The primary aim of this study was to further develop an earlier described algorithm for fusion of radiostereometric analysis (RSA) data and data obtained in 3D computed tomography (CT) for application to the elbow after total joint replacement. The secondary aim was to propose a method for marking of prostheses in 3D CT, enabling definition of a prosthesis-based reference system. Six patients with elbow endoprostheses were investigated. The fusion of data made it possible to visualize the motion axes in relation to the prostheses in the 3D CT volume. The differences between two repeated positioning repetitions of the longitudinal prosthesis axis were less than 0.6 degrees in the frontal and sagittal planes. Corresponding values for the transverse axis were less than 0.6 degrees in the frontal and less than 1.4 degrees (in four out of six less than 0.6 degrees ) in the horizontal plane. This study shows that by fusion of CT and RSA data it is possible to determine the accurate position of the flexion axes of the elbow joint after total joint replacement in vivo. The proposed method for implant marking and registration of reference axes enables comparison of prosthesis function between patients and studies. 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20394932     DOI: 10.1016/j.jbiomech.2010.03.016

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients.

Authors:  Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Uldis Kesteris; Lars Weidenhielm
Journal:  J Orthop Surg Res       Date:  2016-02-24       Impact factor: 2.359

2.  Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties.

Authors:  Volker Otten; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Kjell G Nilsson; Henrik Olivecrona
Journal:  Biomed Res Int       Date:  2017-01-24       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.