Literature DB >> 20394897

Strain-encoded CMR for the detection of inducible ischemia during intermediate stress.

Grigorios Korosoglou1, Stephanie Lehrke, Angela Wochele, Birgit Hoerig, Dirk Lossnitzer, Henning Steen, Evangelos Giannitsis, Nael F Osman, Hugo A Katus.   

Abstract

OBJECTIVES: This study sought to evaluate the diagnostic accuracy of strain-encoded cardiac magnetic resonance (SENC) for the detection of inducible ischemia during intermediate stress.
BACKGROUND: High-dose dobutamine stress cardiac magnetic resonance (DS-CMR) is a well-established modality for the noninvasive detection of coronary artery disease (CAD). However, the assessment of cine scans relies on the visual interpretation of wall motion, which is subjective, and modalities that can objectively and quantitatively assess the time course of myocardial strain response during stress are lacking.
METHODS: Stress-induced ischemia was assessed by wall motion analysis and by SENC in 80 patients with suspected or known CAD and in 18 healthy volunteers who underwent DS-CMR in a clinical 1.5-T scanner. Quantitative coronary angiography was used as the standard reference for the presence of CAD (> or =50% diameter stenosis).
RESULTS: On a patient level, 46 of 80 patients (58%) had CAD, including 20 with single-vessel, 18 with 2-vessel, and 8 with 3-vessel disease. During peak stress, SENC correctly detected ischemia in 45 versus 38 of 46 patients with CAD (7 additional correct findings for SENC), yielding significantly higher sensitivity than cine (98% vs. 83%, p < 0.05). No patients were correctly diagnosed by cine and missed by SENC. During intermediate stress, SENC showed diagnostic value similar to that provided by cine imaging only during peak dobutamine stress (sensitivity of 76% vs. 83%, specificity of 88% vs. 91%, and accuracy of 81% vs. 86%; p = NS for all). Quantification analysis demonstrated that strain rate response is a highly sensitive marker for the detection of inducible ischemia (area under the curve = 0.96; SE = 0.01; 95% confidence interval: 0.93 to 0.99) that precedes the development of inducible wall motion abnormalities and already significantly decreases with moderate 40% to 60% coronary lesions.
CONCLUSIONS: Using SENC, CAD can be detected during intermediate stress with similar accuracy to that provided by cine only during peak stress. By this approach, patient safety may be improved during diagnostic procedures within lower time spent (Strain-Encoded Cardiac Magnetic Resonance Imaging for Dobutamine Stress Testing; NCT00758654). Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20394897     DOI: 10.1016/j.jcmg.2009.11.015

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  33 in total

Review 1.  CMR for characterization of the myocardium in acute coronary syndromes.

Authors:  Erica Dall'Armellina; Theodoros D Karamitsos; Stefan Neubauer; Robin P Choudhury
Journal:  Nat Rev Cardiol       Date:  2010-09-21       Impact factor: 32.419

Review 2.  Assessment of myocardial ischemia with cardiovascular magnetic resonance.

Authors:  Bobak Heydari; Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Prog Cardiovasc Dis       Date:  2011 Nov-Dec       Impact factor: 8.194

Review 3.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

4.  Assessment of global longitudinal strain using standardized myocardial deformation imaging: a modality independent software approach.

Authors:  Johannes H Riffel; Marius G P Keller; Matthias Aurich; Yannick Sander; Florian Andre; Sorin Giusca; Fabian Aus dem Siepen; Sebastian Seitz; Christian Galuschky; Grigorios Korosoglou; Derliz Mereles; Hugo A Katus; Sebastian J Buss
Journal:  Clin Res Cardiol       Date:  2015-02-03       Impact factor: 5.460

5.  Contemporary image-based methods for measuring passive mechanical properties of skeletal muscles in vivo.

Authors:  Lynne E Bilston; Bart Bolsterlee; Antoine Nordez; Shantanu Sinha
Journal:  J Appl Physiol (1985)       Date:  2018-09-20

6.  Quantitative detection of changes in regional wall motion using real time strain-encoded cardiovascular magnetic resonance.

Authors:  Keigo Kawaji; Noreen Nazir; John A Blair; Victor Mor-Avi; Stephanie Besser; Kohei Matsumoto; Jacob P Goes; Darius Dabir; Lukas Stoiber; Sebastian Kelle; Seyedeh Mahsa Zamani; Luise Holzhauser; Roberto M Lang; Amit R Patel
Journal:  Magn Reson Imaging       Date:  2019-09-01       Impact factor: 2.546

Review 7.  Cardiac MRI and Ischemic Heart Disease: Role in Diagnosis and Risk Stratification.

Authors:  Rahul N Sawlani; Jeremy D Collins
Journal:  Curr Atheroscler Rep       Date:  2016-05       Impact factor: 5.113

8.  The Role of Cardiovascular Magnetic Resonance Imaging in Heart Failure.

Authors:  Mark A Peterzan; Oliver J Rider; Lisa J Anderson
Journal:  Card Fail Rev       Date:  2016-11

Review 9.  Identification of left ventricular myocardial ischemia and cardiac prognosis with cardiovascular magnetic resonance: updates from 2008 to 2010.

Authors:  Runyawan Chotenimitkhun; W Gregory Hundley
Journal:  Curr Cardiol Rep       Date:  2011-02       Impact factor: 2.931

10.  Comparison of quantitative wall-motion analysis and strain for detection of coronary stenosis with three-dimensional dobutamine stress echocardiography.

Authors:  Katherine M Parker; Alexander P Clark; Norman C Goodman; David K Glover; Jeffrey W Holmes
Journal:  Echocardiography       Date:  2014-05-12       Impact factor: 1.724

View more